Download Print this page

Technical Specifications - HP ProLiant DL380 Generation 6 Specification

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight (approximate)
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
(per power supply)
DA - 13234 Worldwide QuickSpecs — Version 16 — 8.28.2009
SFF Drives: 3.38 x 17.54 x 27.25 in (8.59 x 44.55 x 69.22 cm)
LFF Drives: 3.38 x 17.54 x 29.25 in (8.59 x 44.55 x 74.30 cm)
Maximum
(all hard drives, power
supply, and processor
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
NOTE: To review typical system power ratings use the HP Power
Advisor which is available online located at url:
energy-efficient
or
www.hp.com/go/hppoweradvisor
Rated Steady-State
Power
Maximum Peak Power
HP ProLiant DL380 Generation 6
60.00 lb (27.27 kg)
47.18 lb (21.45 kg)
100 to 120 VAC
200 to 240 VAC
For 1200 W Power Supply:
10 A (at 100 VAC),
4.9 A (at 200 VAC)
For 750 W Power Supply:
8.9 A (at 100 VAC),
4.3 A (at 200 VAC)
For 460 W Power Supply:
5.5 A (at 100 VAC),
2.6 A (at 200 VAC)
50 to 60 Hz
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
For 750 W Power Supply:
857 W (at 100 VAC),
824 W (at 200 VAC)
For 460 W Power Supply:
526 W (at 100 VAC),
505 W (at 200 VAC)
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
For 750 W Power Supply:
2925 BTU/hr (at 100 VAC),
2812 BTU/hr (at 200 VAC)
For 460 W Power Supply:
1794 BTU/hr (at 100 VAC),
1725 BTU/hr (at 200 VAC)
www.hp.com/go/proliant-
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
For 1200 W Power Supply:
800 W (at 100 VAC),
Page 47

Advertisement

loading