Connection of DSC Antenna
Connection of Handset
Grounding the Transceiver Unit
Connection of AC/DC Power Supply Unit PR-300 (option)
110
100
100V
0
10%
110
100
0
NC
100
0
FAN
100VAC SHIP'S MAINS
16
The DSC antenna is connected to the transceiver unit with a 50 ohm
coaxial cable, type 5D-2V. Attach an M-type plug to the cable (if
necessary) as shown in Figure 6. Screw the plug into the CH70 ANT
connector at the rear of the transceiver unit.
Connect the handset cable to the HANDSET connector on the rear
panel.
Fasten a ground wire (local supply) between the GND terminal at the
rear of the transceiver unit and ship's hull (or ground bus).
CAUTION
Ground the equipment to
prevent electrical shock
and mutual interference.
Changing tap connections
Change the tap connections of the transformer according to input
voltage.
110
100
110V
0
10%
110
100
0
NC
100
0
FAN
110VAC SHIP'S MAINS
Figure 7 Tap connections in the PR-300
110
100
200V
0
10%
110
100
0
NC
100
0
FAN
200VAC SHIP'S MAINS
110
100
220V
0
10%
110
100
0
NC
100
0
FAN
200VAC SHIP'S MAINS