4. INSTALLATION
Fuse holder
Cable tie
How to fix fuse holders
Establishing the ground
The ground wire (1.25 sq or more, local
supply) should be as short as possible. The
signal line ground is isolated from the chassis
ground, however the power line is not insu-
lated. Therefore, when connecting eternal
equipment having positive ground, do not
ground the signal line to the chassis. If exces-
sive noise shows on the screen, the ground
may be inadequate. In this case, attach a
steel plate measuring 20 cm by 30 cm on the
outside of the hull to provide a ground point.
Connect the ground wire there. Use a
"closed" type lug (
tion at the display unit. Do not use an "open"
type lug (
).
Optional equipment
Power connector
The power supply port is commonly used for
connection of external equipment such as a
GPS receiver or wind indicator. Refer to the
interconnection diagram to connect cables.
Connector
1
TD-A
2
TD-B
3
RD-A
4
RD-B
5
TEMP-IN
6
TEMP-IN-0V
7
DC-P-IN (+)
8
DC-M-IN (-)
9
NC
10
SHIELD
Power supply lines
(red and black)
) to make the connec-
Color
Remarks
WHT IEC61162-1/
NMEA0183
BLU
YEL
IEC61162-1/
NMEA0183
GRN
BRN
Temperature
analog input
ORG
RED
Power input
12-24 VDC
BLK
-
-
Pin assignment (front view)
Water temp/speed sensor
Connect the optional water temp/speed
sensor to the XDR port with the optional con-
version cable (Type 02S4147) as shown
below.
Connect to XDR port
at rear of display unit
MJ-A6SRMD
Tape connectors with
vulcanizing tape
and then vinyl tape
to waterproof them.
Bind tape ends with
cable ties to prevent
tape from unraveling.
From
sensor
Connection of conversion cable 02S4147
Optional transducer
The optional matching box (Type: MB-1100,
Code No.: 000-041-353) is required to con-
nect the optional transducers 50B-6, 50B-6B,
200B-5S, 50/200-1T.
50kHz
Transducer
50B-6/6B
TB2
SHIELD
RED
RED
BLK
200kHz
BLK
200B-5S
Detach grommet;
attach cord lock.
Matching box MB-1100, cover removed
36
8
1
2
7
9
6
3
10
5
4
MJ-A10SPF
MJ-A10SRMD
From
transducer
Jumper block setting
J2: No output reduction (default)
J1: Output reduction
02P6348
J2
J1
Green
(shield)
1
TB1
WHT
2
3
3
2
4
1
BLK
5
Connect 10P
connector to
XDR port on
rear of
display unit.

Hide quick links: