1.
Check local building
codes.
• Some building codes require direct wiring to a
branch circuit. If direct wiring is NOT required,
plug door operator into grounded outlet
(Fig. 6-1).
2.
Return to Section 3 for SAFE-T-BEAM ® System
alignment
and troubleshooting.
1.
Disconnect the power cord from the branch
circuit mains.
2.
Remove bottom
cover from power head.
• Remove four (4) hex head screws from front
and rear covers.
• Slide bottom cover off.
3.
Remove existing
power cord from power head.
• Disconnect three power cord wires.
• Remove and discard power cord.
• Remove 7/8" diameter knock-out plug.
• Install a suitable entrance bushing.
4.
Install permanent
wiring to power head.
For Stealth--connect
permanent wiring to
internal terminal
block.
• Connect white supply line to silver terminal.
• Connect black supply line to brass terminal.
• Connect ground wire to green wire location
(GROUND).
For ProMax--connect
permanent wiring.
• Make connections with UL recognized wire nuts.
• Connect white supply line to white wire.
• Connect black supply line to black wire.
• Connect ground wire to green wire location
(GROUND).
• Wires inside operator are to be a minimum of
6 inches.
5.
Replace power head bottom cover.
• Replace and tighten four (4) hex head screws.
cover i:_ on po_:,r
head befio_,!_ope_d<on
Operator
power
cord
Grounded
outlet