Furuno FR-2135S Installation Manual page 48

Furuno marine radar user manual
Hide thumbs Also See for FR-2135S:
Table of Contents

Advertisement

Setting method 1: by gyrocompass specifications
1) Gyrocompass type
Gyrocompass
SW
type
1-4
AC synchronous
OFF OFF
DC synchronous
OFF OFF
DC step
ON
Full-wave
OFF
pulsating current
Half-wave
ON
pulsating current
3) Rotor voltage
(between R1 & R2)
Rotor voltage
SW 2-1
20 V to 45 VAC
ON
30 V to 70 VAC
OFF
40 V to 90 VAC
ON
60 V to 135 VAC
OFF
5) Ratio
Ratio
SW1-1
SW 1-2
360x
OFF
OFF
180x
ON
OFF
90X
OFF
ON
36X
ON
ON
7) AD-10 format data
Tx interval
Select data transmitting interval for ports 1 to 6 by jumper wires
JP6 and JP7.
Note: The Tx interval is available in 25 ms or 200 ms.
25 ms is for radar; 200 ms is for all other equipment.
9) NMEA-0183
Version no.
Version no.
SW3-1
1.5
OFF
2.0
ON
SW
SW
JP1
1-5
1-6
OFF #1,
#2, #3
OFF #2,
#3, #4
OFF
OFF #4,
#5, #6
ON
OFF #4,
#5, #6
ON
OFF #4,
#5, #6
4) Stator voltage
(between S1 and S2)
JP3
Stator voltage
#2
20 V to 45 VAC, or
20 V to 60 VDC
#2
#1
20 V to 45 VAC, or
20 V to 60 VDC
#1
40 V to 90 VAC
60 V to 135 VAC
6) Supply voltage
SW1-3
Supply voltage
OFF
20 V to 45 VAC, or
20 V to 60 VDC
OFF
OFF
30 V to 135 VAC, or
40 V to 100 VDC
OFF
10) NMEA-0183
Baud rate
Baud rate
SW3-2
4860bps
OFF
38400bps
ON
2) Frequency
Frequency
SW
1-7
50/60Hz
OFF
400Hz
ON
500Hz
OFF
DC
ON
SW 2-2
SW 2-3
ON
OFF
ON
OFF
JP4
#2
#1
8) NMEA-0183
Tx interval and Output sentence
Tx
interval
1 s
200 ms
100 ms
25 ms
11) NMEA-0183
Talker
Talker
AG
HE
4-4
SW
Remarks
1-8
OFF AC synchronous
pulsating current
OFF AC synchronous
pulsating current
ON
AC synchronous
pulsating current
ON
DC synchronous
DC step
JP2
OFF
#2
OFF
#2
OFF
#1
OFF
#1
JP5
#2
#1
SW
SW
Output
2-5
2-6
sentence
OFF
OFF
HDT+VHW
ON
OFF
OFF
ON
ON
ON
SW3-3
OFF
ON
HDT
HDT
HDT

Advertisement

Table of Contents
loading

Table of Contents