Connections
Open the display unit and fix it with the stay. (For procedure see page 1-6.) Re-
move the shield cover from the INT Board. Connect signal, power, gyro and log
cables as shown on the next page. Optional equipment are connected to the INT
Board. Be sure to ground the display unit.
PTU BOARD
03P9245
MOTHER BOARD
03P9251
INT BOARD
03P9252
J450
J457
J442
J458
J443
J455
J453
J444
J466
J451
J462
J463
J452
J456
Scanner
Unit
Fasten shield here.
(Tabletop type)
Connect coax
cable here.
DJ1
J5
J448
J4
GYRO CONVERTER
BOARD 64P1106
Location of connectors
J445
on the INT Board. See
next page for connector
description.
J454
J448
J446
J467
J449
J465
Figure 2-5 Display unit, inside view
2-4
Ship's
Gyro
Log
Ground terminal
(Tabletop type)
Terminal
board
Fasten shields
here together.
(Console type)
POWER switch
(for maintenance,
always ON)
Fasten TX-HV
line to #1 termanal.
To fasten;
1. Slide terminal.
2. Lift terminal to
remove.
Fix the DJ1 connector with
teo M3x8 screw )supplied).
CAUTION
Ground the equipment to
prevent electrical shock
and mutual interference.
Bind the cables so as not to pinch them
between the monitor and mounting base.
Take special care with the high voltage
line.