Burner Flame Pattern - Desa Comfort Glow CGCF26TN Owner's Operation And Installation Manual

Vent-free natural gas compact fireplace
Hide thumbs Also See for Comfort Glow CGCF26TN:
Table of Contents

Advertisement

INSPECTING
BURNER
Contmued
BURNER
FLAME
PATTERN
Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than one inch above the log.
Note: When using the fireplace the first time, the flame will be yellow for approxi-
mately one hour until the log cures.
WARNING
If yellow tipping occurs, your fireplace
could produce
increased
levels of carbon monoxide,
if burner flame pattern
shows yellow
tipping,
follow instructions
at bottom of this page.
NOTICE
Do not mistake orange flames with yellow tipping.
Dirt or other fine
particles
enter the fireplace
and burn causing
brief patches
of
orange flame.
I Top of
Flame
About One
Inch Above
Logs
CORRECT FLAME PA'FFERN
AT HIGH POSITION
Figure 25 - Correct Burner Flame Pattern
i tl
h l_
INCORRECT FLAME PATTERN
AT HIGH POSITION
Figure 26 - Incorrect Burner Flame Pattern
If burner flame pattern is incorrect, as shown in Figure 26
• turn fireplace off (see To Turn OffGas to Appliance,
page 21).
• see Troubleshooting,
pages 24 through 27.
|
1O3668

Advertisement

Table of Contents
loading

Table of Contents