OBSERVED
POSSIBLE
PROBLEM
CAUSE
REMEDY
103668
TROUBLE-
SHOOTING
Continued
When ignitor button
is pressed, there is
spark at ODS/pilot
but no ignition
I. Gas supply turned off
or manual shutoff
valve closed
2. Control knob not in
PILOT position
3. Control knob not
pressed in while in
PILOT position
4. Air in gas lines when
installed
5. ODS/pilot
is clogged
6. Gas regulator
setting is
not correct
1. Turn on gas supply or
open manual shutoff
valve
2. Turn control knob to
PILOT position
3. Press in control knob
while in PILOT
position
4. Continue
holding
down control knob.
Repeat igniting opera-
tion until air is re-
moved
5. Clean ODS/pilot
(see
Cleaning and Mainte-
nance, page 24) or
replace ODS/pilot
assembly
6. Replace gas regulator
ODS/pilot
lights but
flame goes out when
control knob is
released
1. Control knob not fully
pressed in
2. Control knob not
pressed in long enough
3. Safety interlock system
has been triggered
4. Manual shutoff valve
not fully open
5. Thermocouple
connec-
tion loose at control
valve
6. Pilot flame not touch-
ing thermoconple,
which allows thermo-
couple to cool, causing
pilot flame to go out.
This problem could be
caused by one or both
of the following:
A) Low gas pressure
B) Dirty or partially
clogged ODS/pilot
7. Thermocouple
dam-
aged
8. Control valve damaged
1. Press in control knob
fully
2. After ODS/pilot
lights,
keep control knob
pressed in 30 seconds
3. Wait one minute for
safety interlock system
to reset. Repeat
ignition operation
4. Fully open manual
shut-off valve
5. Hand tighten until
snug, then tighten 1/4
turn
more
6. A) Contact local
natural gas company
B) Clean ODS/pilot
(see Cleaning and
Maintenance,
page 24)
or replace ODS/pilot
assembly
7. Replace thermooouple
8. Replace control valve
Continued