CHECKING
GAS
CONNECTIONS
WARNING
Test all gas piping and connections
for leaks after installing
or
servicing.
Correct all leaks at once.
WARNING
Never use an open flame to check for a leak. Apply a mixture
of
liquid soap and water to all joints.
Bubbles
forming
show a leak.
Correct all leaks at once.
PRESSURE
TESTING
GAS SUPPLY
PIPING
SYSTEM
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect fireplace and its individual
manual shutoff valve from gas supply
piping system. Pressures
in excess of 1/2 psig will damage fireplace
regulator.
2, Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize
supply piping system by either using compressed
air or
opening main gas valve located on or near gas meter.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and
water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 19).
2. Pressurize
supply piping system by either using compressed
air or opening main
gas valve located on or near gas meter.
3. Check all joints from gas meter to manual shutoff valve (see Figure 20). Apply
mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE
TESTING
FIREPLACE
GAS CONNECTIONS
1, Open manual shutoff valve (see Figure 19).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of fireplace is in the OFF position.
4, Check all joints from manual shutoff valve to thermostat gas valve (see Figure 20).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operating
Fireplace,
pages 19 through 21). Check all other
internal joints for leaks.
7. Turn off f'neplace (see To Turn Off Gas to Appliance,
page 21 ).
8. Replace front panel.
•,_ --
Open
Closed
Manual
Shutoff
Valve
Figure 19 - Manual Shutoff Valve
Manual
_,
Shutoff
Gas Meter
_
Valve
.". '
"o2,1,
_
Figure 20 - Checking Gas Joints
m
I036_

Advertisement

Table of Contents
loading

Table of Contents