INSPECTING
BURNER
Check pilot flame pattern and burner flame pattern often.
PILOT
FLAME
PATTERN
Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching
the thermocouple.
This will
cause the thermocouple
to cool. When the thermocouple
cools, the fireplace will
shut down.
Pilot Burner
Figure 23 - Correct Pilot Flame Pattern
Thermocou
Pilot Burner
Figure 24 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect,
as shown in Figure 24
• turn fireplace off (see To Turn OffGas
to Appliance,
page 21).
• see Troubleshooting,
pages 24 through 27.