AIR FOR
COMBUSTION
AND
VENTILATION
Continued
WARNING
If the area in which the heater may be operated
is smaller
than
that defined
as an unconfined
space, provide
adequate
combus-
tion and ventilation
air by one of the methods
described
in the
National
Fuel Gas Code, ANSI Z223.1,
1992, Section
5.3 or appli-
cable local codes.
VENTILATION
AIR
Ventilation
Air From Inside
Building
This fresh air would come from an adjoining
unconfined
space. When ventilating
to
an adjoining unconfined
space, you must provide two permanent openings:
one within
12" of the ceiling and one within 12" of the floor on the wall connecting
the two spaces
(see options 1 and 2, Figure 4). You can also remove door into adjoining
room (see
option 3, Figure 4). Follow
the National
Fuel Gas Code NFPA
54/ANSI
Z223.1,
Section 5.3, Air for Combustion
and Ventilation
for required size of ventilation
grills
or ducts.
WARNING
Rework
worksheet,
adding
the space of the adjoining
unconfined
space. The combined spaces must have enough fresh air to supply all
appliances
in both spaces.
Ventilation
Gdlls
Or
into Adjoining
Remove
Room,
Door into
Option 1
Adioining
Room,
Option 3
ventilation Grills
Into Adjoining Room,
Option 2
Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel