CLEANING
AND
MAINTENANCE
TROUBLE-
SHOOTING
Note:
All troubleshooting
items
are listed in order of
operation.
m
WARNING
Turn off fireplace
and let cool before cleaning.
CAUTION
You must keep control
areas, burner, and circulating
air passage-
ways of fireplace
clean. Inspect these areas of fireplace
before each
use. Have fireplace
inspected
yearly by a qualified
service person.
Fireplace
may need more frequent
cleaning
due to excessive
lint
from carpeting,
bedding
material,
etc.
ODS/PILOT
AND BURNER
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized
air to clean.
Exterior
• Use a soft cloth dampened
with a mild soap and water mixture. Wipe the
cabinet to remove dust.
WARNING
Turn off and unplug fireplace
and let cool before servicing.
Only a
qualified
service
person should
service and repair fireplace.
CAUTION
Never use a wire, needle, or similar object to clean ODS/pilot.
This
can damage ODS/pilot
unit.
OBSERVED
POSSIBLE
PROBLEM
CAUSE
REMEDY
When ignitor button
is pressed, there is no
spark at ODS/pilot
1. Ignitor cable pinched or
wet
2. Ignitor electrode not con-
nected to ignitor cable
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode
broken
6. Ignitor electrode
posi-
tioned wrong
1. Free ignitor cable if
pinched by any metal or
tubing. Keep ignitor
cable dry
2. Reconnect
ignitor cable
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace ignitor
6. Replace ignitor
1O3668