TROUBLESHOOTING
GUIDE
I
VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE
EXPOSED WHEN REPAIRING THE COMPRESSOR.
PERSONAL INJURY CAN
OCCUR. UNPLUG THE COMPRESSOR BEFORE AI-rEMPTING ANY REPAIRS.
PROBLEM
CAUSE
SOLUTION
Air Leaks
Hose fitting loose.
Tighten fitting.
Prolonged
excessive
use of air.
Compressor isnot delivering
enough air.
Motor will not run.
High discharge
pressure.
Cannot be adjusted lower.
Hole in hose.
Air leaks.
Fuse blown, circuit breaker tripped.
Extension cord is wrong length or
gauge.
Loose electrical
connections.
Faultymotor.
Adjustable pressu re valve not func-
tioning.
Decrease the amount of air usage. Your com-
3ressor is not large enough for the air require-
meat.
Replace the hose.
Tighten fittings.
1,
Check fuse box for blown fuse and replace as
necesssary. Reset circuit breaker. Do not
use a fuse or circuit breaker with higher rating
than that specified for your particular branch
circuit.
2. Check for proper fuse. You should be using
a Quick Acting fuse.
3. Check for low voltage problem.
4. Check the extension cord.
5. Disconnect the other electrical appliances
from circuit or operate the compressor on its
own branch circuit.
Check the extension cord.
Check wiring connection inside terminal box
Have checked at a local Service Center.
RISK OF BURSTING.
DO NOT OPER-
ATE THE COMPRESSOR IF THIS PROB-
LEM EXISTS. ADJUSTABLE PRESSURE
VALVE MUST BE REPLACED.