GASSUPPLY
• A 1/8-in.
NPT thread
plugged
tapping,
accessible
for test
gauge connection,
must be installed
immediately
upstream
of the gas supply connection
to the dryer. Contact
your lo-
cal gas utility should you have questions on the installation
of the plugged
tapping.
• Supply
line is to be 1/2-in.
rigid pipe and equipped
with an
accessible
shut-off
within
6 ft. of, and in the same room
with the dryer.
• Use pipe thread
sealer compound
or Teflon tape appropri-
ate for natural
or LP gas.
• You must use with this dryer a flexible
metal connector
listed ANSI Z21.24 / CSA 6.10. The length of the connector
shall not exceed
3 ft.
• Connect flexible
metal connector
to dryer
and gas supply.
• Open shut-off
valve.
3o Reconnecting
gas
Listed connector ANSI Z21.24 / CSA 6.10
Apply pipe compound
to the adaptor and
appliance gas inlet.
Tighten the flexible
gas line to
the adaptor
using 2 adjustable
wrenches
Back of
a
Flare
3/8"
NPT inlet
from
appliance
NPT
Adaptor
New metal
flexible gas
line connector
45 ° elbow
Adaptor
1/8" NPT plugged
tapping
for checking
gas inlet pressure
valve
size at least 1/2"
FLOOR
ITEMS NOT SUPPLIED
Note: The connector
and fittings
are designed
for use only on
the original
installation
and are not to be reused for another
appliance
or at another
location.
Keep flare end of adaptor
free of grease, oil and thread
sealant.
CAUTION: Use adapters as shown. Connector nuts must not
be connected directly to pipe threads.
_
pply pipe compound
to all male threads
TIGHTEN
ALL CONNECTIONS
USING
TWO
ADJUSTABLE
WRENCHES.
DO NOT OVERTORQUE
GAS CONNEC-
TIONS!
23