4_ Leak Test
NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS.
Open gas valve
Check all connections
for leaks with soapy solution or
equivalent.
Apply
soap solution, bubbles
indicate
leaks. Leak
test solution
must not contain
ammonia
which could cause
damage
to the brass fittings.
If leaks are found, close valve,
retighten
the joint, and repeat the soap test.
5o IElectrical
connection
infonmation
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK
AND
PERSONAL
INJURY:
• DO NOT USE AN EXTENSION
CORD OR AN ADAPTER
PLUG WITH
THIS APPLIANCE.
Appliance
must be electrically
grounded
in accordance
with
local codes and ordinances,
or in the absence
of local codes,
in accordance
with the NATIONAL
ELECTRICAL CODE,
ANSI/NFPA
NO. 70.
ELECTRICAL
REQUIREMENTS
This appliance
must be supplied
with 120 V, 60 Hz, and con-
nected to a properly
grounded
branch
circuit, protected
by a
15- or 20- amp circuit
breaker
or time- delay
fuse. If electri-
cal supply provided
does not meet the above specifications,
it is recommended
that a licensed electrician
install an ap-
proved
outlet.
USE A THREE-PRONG
(GROUNDING)
PLUG FOR
YOUR PROTECTION
AGAINST
SHOCK
HAZARD.
IT SHOULD
BE PLUGGED
DIRECTLY INTO
A PROP-
ERLY GROUNDED
THREE-PRONG
RECEPTACLE.
DO NOT CUT OR REMOVE
THE GROUNDING
PRONG
FROM
THIS PLUG.
24
ENSURE PROPER GROUND
EXISTS BEFORE USE.
GROUNDING
INSTRUCTIONS
This appliance
must be grounded.
In the event of malfunction
or breakdown,
grounding
will reduce the risk of electric
shock by providing
a path of least resistance
of electric
cur-
rent. This appliance
is equipped
with a cord having an equip-
ment-grounding
conductor
and a grounding
plug. The plug
must be plugged
into an appropriate
outlet that is properly
installed
and grounded
in accordance
with all local codes
Improper
connection
of the equipment-grounding
conductor
can result in a risk of electric
shock.
Check with
a qualified
electrician
or serviceman
if
you are in doubt
as to whether
the appliance
is
properly
grounded.
Do not modify
the plug provided
with the appliance.
If it will
not fit the outlet, have a proper outlet
installed
by a quali-
fied electrician.
6o Exhaust
information
IN CANADA
AND
IN THE UNITED
STATES, THE RE-
QUIRED
EXHAUST
DUCT DIAMETER
IS 4 IN (102
mm). DO NOT
USE DUCT LONGER
THAN
SPECI-
FIED IN THE EXHAUST
LENGTH
TABLE.
Using exhaust longer than specified
length will:
• Increase the drying
times and the energy cost.
• Reduce the dryer
life.
• Accumulate
lint, creating
a potential
fire hazard.
The correct
exhaust
installation
is YOUR RESPONSIBILITY.
Problems clue to incorrect
installation
are not covered
by
the warranty.
Remove and discard
existing
plastic or metal
foil transition
duct and replace
with UL listed transition
duct.
The MAXIMUM
ALLOWABLE
duct length and number
of
bends of the exhaust system depends
upon the type of duct,
number of turns, the type of exhaust hood (wall cap), and all
conditions
noted below. The maximum
duct length for rigid
metal duct is shown in the table
below.