Capturing Data
3
Figure 27
Alaising

Oscilloscope Bandwidth and Sample Rate

An oscilloscope's bandwidth is typically described as the lowest frequency
at which input signal sine waves are attenuated by 3 dB (- 30% amplitude
error).
At the oscilloscope bandwidth, sampling theory says the required sample
rate is f
= 2f
. However, the theory assumes there are no frequency
S
BW
components above f
(f
in this case) and it requires a system with
MAX
BW
an ideal brick- wall frequency response.
Agilent 3000 Series Oscilloscopes User's Guide
63