Connecting the Systems to Power Through PDUs

1. Locate one black and one gray power cable (jumper).
2. Connect oneend of each gray cable to the receptacle on the top
CPU- I ⁄ O enclosure. Connect the other end of each gray cable to the top PDU.
!
3. Connect the end of each black cable to the receptacle on the left
CPU- I ⁄ O enclosure. Connect the other end of each black cable to the bottom
PDU.
4. From the front of the system, make sure that the CPU- I ⁄ O enclosures are fully
inserted in the shelf unit by tightening, if necessary, the thumbscrews. Then, at the
rear of the system, turn the power interlock mechanisms into the locked position.
See
Chapter 5, "Installing PDUs"
C A U T I O N
Make sure the power interlock mechanism is unlocked
when you insert the power cord. On rack-mounted
systems, the unlocked position is vertical and on pedestal
systems the unlocked position is horizontal. In
and in
Figure
4-2, the interlock mechanism, located
beneath the power connector, is shown in the unlocked
position. In
Figure 4-3
mechanism is shown in the locked position.
Connecting the System to Electrical Power
and in
Figure
4-4, the interlock
for more information about the PDUs.
Figure 4-1
Setting Up Your System
4-13