Performance Data Sheet - Kenmore 106.5478 Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model PIKB2/PIRFKB2
Capacity
200 Gallons
(757 Liters) without
Filter Indicator
Light
System tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of
(_
Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of
Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts,
Turbidity, Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Styrene, Chlorobenzene
and Ethylbenzene.
This system has been tested
according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below.
The
concentration
of the indicated
substances
in water
entering
the system was reduced
to a concentration
less than or equal
to the
permissible
limit for water
leaving
the system, as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Minimum %
Average %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.10 mg/L
2.0 mg/L + 10%
0.05 mg/L
**
97.6
97.6
Particulate Class I*
85% reduction
21000000#/mL
At least 10,000 particles/mL
140000 #/mL
99
99.5
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L + 10%
1.0 ug/L
99.3
99.3
Lead: @ pH 8.5
0.010 mg/L
160 ug/L
0.15 mg/L _+10%
2.0 ug/L
98.7
99.3
Mercury: @ pH 6.5
0.002 mg/L
5.8 ug/L
0.006 mg/L + 10%
0.3 ug/L
94.9
96.6
Mercury: @ pH 8.5
0.002 mg/L
6.1 ug/L
0.006 mg/L _+10%
0.4 ug/L
93.4
95.3
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
96.7
96.7
O-Dichlorobenzene
0.6 mg/L
1900 ug/L
1.8 mg/L _+10%
0.7 ug/L
99.9
99.9
Toxaphene
0.003 mg/L
14 ug/L
0.015 mg/L _+10%
1.0 ug/L
91.5
92.8
Atrazine
0.003 mg/L
9.0 ug/L
0.009 mg/L _+10%
0.5 ug/L
94.5
94.5
Asbestos
99%
130 MFL
107to 108fibers/L tt
0.17 MFL
99
99
Live Cysts _
>99.95%
96,000/L
50,000/L min.
1/U
99.99
99.99
Turbidity
0.5 NTU
12 NTU
11 _+1 NTU
0.4 NTU
96.7
98.5
Alachlor
0.002 mg/L
41 ug/L
0.04 mg/L _+10%
1.0 ug/L
97.6
97.6
Endrin
0.002 mg/L
5.9 ug/L
0.006 mg/L _+10%
0.2 ug/L
96.5
96.6
Ethylbenzene
0.7 mg/L
2100 ug/L
2.1 mg/L _+10%
0.5 ug/L
99.9
99.9
Lindane
0.0002 mg/L
1.9 ug/L
0.002 mg/L _+10%
0.02 ug/L
99
99
Chlorobenzene
0.1 mg/L
2100 ug/L
2.0 mg/L _+10%
1.1 ug/L
99.9
99.9
Tetrachloroethylene
0.005 mg/L
14 ug/L
0.015 mg/L _+10%
0.5 ug/L
96
96.4
Styrene
0.1 mg/L
2200 ug/L
2.0 mg/L _+10%
ND (0.5)
99.9
99.9
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Model
PIKB2:
Change the water filter cartridge
every 6 months.
If the water flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter
cartridge
more often.
Use replacement
cartridge
P1 RFKB2,
part #9030.
2008 suggested
retail price of $59.99
U.S.A./S71.99
Canada.
Prices are subject
to change
without
notice.
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters that may contain
filterable
cysts.
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.