Download Print this page

Sears Kenmore 75161 Use & Care Manual page 39

Advertisement

Available languages

Available languages

B Standard Twin Burner ModeJs
(models with lift-up cooktops)
1. Lift the cooktoF
2. Lift
the
burner
assemblies
straight
up
and
set aside
to gain
access to surface
burner spuds.
3. With
a
7mm,
_
._'.,.
5/16"
or a small
/_1
adjustable
_ _ _._..
wrench
(depend-
"-.\
ing
on the
size
needed),
remove
= Brass
Silver
)
each of the four spuds on the surface
burner
gas
inlet tubes and replace
them with the correct
gas
spuds
mounted
in a holder
at the right rear of the
range,
above the regulator_
Natural gas spuds are
brass and LP gas spuds
are red or silver_ (Mount
the spuds
that you removed
from the inlet tubes
back in the holder.)
To prevent leakage,
make sure
spuds are securely
screwed
into gas inlet tubes.
4. Replace the burner assemblies.
5. Keep all spuds with your range so you have them if
you move or get a different
gas hook-up.
Top Burner
Orifice
Drill Size
Color
Natural
Gas
#54 (.0550 Di&)
Brass
LP (Propane)
#66 (.0330 Din)
Red or Silver
Step
3
Convert Oven Thermostat
(for models equipped
with Standing
Pilots)
1. Remove
the OVEN CONTROL
knob.
2. Locate the gas selector
screw
at the
left of the
thermostat
shaft° Turn the screw until the
small pointer stops at LP or N,
depending
on the type of gas
you
are
converting
too The
most
the screw
will move
is
1/2 a turn.
3. Replace the OVEN CONTROL
knob.,
Step
4
Convert the Oven Burner Orifices
Oven Burner
1. Remove
oven door, storage
drawer
or broiler draw-
er and oven bottom° The lower burner orifice spud
is located behind the storage drawer, broiler drawer
or kick panet_ (On some
models,
a metal shield
must be removed to access
the orifice°)
2,
To convert
to LP gas,
use a
1/2" wrench
to turn the lower
burner
orifice
spud
clockwise.,
Tighten
the spud only until it is
snug.. To prevent
damage,
do
not overtighten
the spud.
To convert
to natural
gas,
loosen the spud about 2 turns,.
Broil Burner (on some models)
To convert
to LP gas, use a 1/2" wrench
to turn the
upper
burner
orifice
spud
clockwise.
Tighten
spud
only until it is snug with the base, To prevent damage,
do not overtighten
spud.
To convert
to natural
gas,
loosen
the spud about
2 turns.
$t®p
5
Convert Air Adjustment Shutter(s)
..oosen
head screw and rotate the shut-
ter to the full open position.
With
baffle
in place,
flames
should
have approximately
1" (2°5 cm)
Screw
blue
cones
and
should
not
Air
extend beyond
the edges of the
Shutter
burner
baffle,. After 30 seconds
tM.
of burner
operation,
check
for
flames
lifting off burner
ports.
If lifting
is observed,
gradually
reduce
air shutter
opening
until flames
are
stabilized.
For
natural
gas,
the shutter
should
be open
1/2"
(1,3 cm) or about 3/4 of the way open_
(continued next page)
39

Advertisement

loading

This manual is also suitable for:

Kenmore 75261Kenmore 75268Kenmore 75168