Download Print this page

Sears Kenmore 75161 Use & Care Manual page 37

Advertisement

Available languages

Available languages

Converting tG LP Gas (o,
C onverting
Back to Natural
Gas from LP)
This range leaves the factory set for use with natural gas.
If you convert to LP gas, keep these instructions
and ori-
fices in case you want to convert back to natural gas.
The conversion
should be done by a qualified technician
or installer
Prepare the Range for Conversion
CAUTION--Before
converting
the range:
(1) Turn off gas supply at the wall and
(2) Turn off the electrical power to the range.
If range has not yet been connected
to gas supply, or
if flexible connection
was made, range may be pulled
out from the wall to make conversion
easier.
TooJs Required:
o Adjustable
wrench
= 1/2" open-end
wrench
o Flat blade screwdriver
(small)
o Nut drivers:
9/32" or 7mm (for sealed burners)
o Nut drivers
or wrenches:
7mm,
5/16"
or a small
adjustable
(for standard
twin burners)
Step
t
Convert The Pressure Regulator
WARNING:
Do not remove
the
pressure
regu-
lator from the range.
1. Remove
the storage
drawer,
broiler drawer
or kick
panel and locate the pressure
regulator
at rear of
the range.
Remove Screws_
I
Access Cover
On some models,
you may have to remove an access
cover also.
For
models
equipped
with
standard
twin
burners,
remove
the cooktop
and locate the pressure
regula-
tor at the right rear of the range.
2. Follow the directions
in A for Sealed Burner Models
(models without
a Iift-up cooktop)
or B for Standard
Pwin Burner Models (models
with a lift-up cooktop)
that match your regulator
type.
A Sealed Burner Models
(models without lift-up cooktops)
If It Is This Regulator:
Levershown
closed, PULL
TO OPEN,
Gas Flow into
Range
LP
nut and pin
NAT
1, Use an adjustable
wrench
to remove
the nut from
the pressure
regulator.
2. Apply sideward
finger pressure
to remove the plas-
tic pin from the nut.
HINT: To remove the pin, place the nut on a flat sur-
face and press the pin sideways
with your fingers.
3. Push down on the disc edges to replace the pin in
the nuL
_,_
NAT
I
I
0
LP
I
4. Reinsert
the assembly
into the regulator.
B Standard Twin Burner Models
(models with lift-up cooktops)
If it Is This Regulator:
NAT-_
_._._
LP
Cap
Cap
Gas Flow
.
into Range
"_k,_ I I!_"_F-_
Lever shown
- " FuL° °sed-
ENLTOOP
1. Use a Coin to remove
the cap from the pressure
regulaton
2. Turn
the
cap
over
and
hook
it into
the
slots.
The type of gas to be used should
now be visible
on the top of the cap.
(continued next page)
37

Advertisement

loading

This manual is also suitable for:

Kenmore 75261Kenmore 75268Kenmore 75168