I. Install
a manual
gas line shut-off
valve in the gas
line in an easily
accessed
location
outside
of the
range.
Make
sure
everyone
operating
the range
knows where and how to shut off the gas supply to
the range
2, Install male 1/2" flare union adapter to the 1/2" NPT
internal
thread
elbow at inlet of pressure
regulator
On models
equipped
with dual burners,
install the
male pipe thread end of the 1/2" flare union adapter
to the 1/2" NPT internal
thread
at inlet of pressure
regulator
Use a backup wrench on the regulator
fit-
ting to avoid damage.
When
installing
the range from the front, remove the
90 ° elbow for easier installation.
3. Install male 1/2" or 3/4" flare union adapter
to the
NPT internal
thread
of the manual
shut-off
valve,
taking care to back-up
the shut-off
valve to keep it
from turning
4. Connect
flexible
metal
appliance
connector
to the
adapter
on the range° Position
range to permit con-
nection at the shut-off
valve
5;. When all connections
have been made, make sure
all range controls
are in the off position and turn on
the main gas supply valve. Use a liquid leak detec-
tor at all joints and connections
to check for leaks
in the system°
I CAUTION:
DO NOT USE A FLAME
TO CHECK
FOR GAS LEAKS.
When
using
test pressures
greater
than
1/2 psig to
pressure
test the gas supply system
of the residence,
disconnect
the range
and individual
shut-off
valve
from the gas supply
piping.
When
using
test pres-
sures of 1/2 psig or less to test the gas supply
sys-
tem, simply isolate the range from the gas supply sys-
tem by closing the individual
shut-off
valve°
Step
Eiectrican Connections
(on some models)
Electrical
Requirements
120-volt,
60 Hertz,
properly
grounded
branch
circuit
protected
by a 15-amp
or 20-amp
circuit
breaker
or
time delay fuse.
Extension
Cord Cautions
Because
of potential
safety hazards
associated
with
certain
conditions,
we strongly
recommend
against
the use of an extension
cord_ However,
if you still elect
to use an extension
cord, it is absolutely
necessary
that it be a UL-listed,
3-wire grounding4ype
appliance
extension
cord and that the current
carrying
rating of
the cord in amperes
be equivalent
to, or greater than,
the branch
circuit rating
Grounding--IMPORTANT
(Please
read carefully)
FOR PERSONAL
SAFETY, THIS APPLIANCE
MUST
BE PROPERLY
GROUNDED.
The power
cord of this appliance
is equipped
with a
three-prong
(grounding)
plug which mates with a
standard
three-prong
grounding
wall recepta-
cle to minimize
the pos-
sibility
of electric
shock
hazard
from this applF
anceo
The
customer
should
have the wall receptacle
PREFERRED
METHOD
_
-"_,_,-"_
_'f
Ensure proper
,It/ground
exists
Iif°
before use
and circuit checked
by a qualified
electrician
to make
sure the receptacle
is properly
grounded
Where
a standard
two-prong
wall
receptacle
is
encountered,
it is the personal
responsibility
and obli-
gation of the customer
to have it replaced
with a prop-
erly grounded
three-prong
wal! receptacle
DO NOT, UNDER
ANY ClRCU_STANCES,
CUT OR
REMOVE
THE THIRD
(GROUND)
PRONG
FROM
THE POWER
CORD,
(continued next page)
3I