Bypassing Protection Zones (cont'd)

Zones Remaining Bypassed After Disarming

The system provides an option to allow all manually bypassed zones to remain
bypassed upon disarming (security code + OFF) of the partition. This option must be
programmed by your installer. Check with your installer to see if this option has been
enabled.
NOTES:
For each partition in which the option is enabled, the security code + OFF will no
longer unbypass zones. To unbypass ALL zones you must enter your security code + #
+ 64. To unbypass zones INDIVIDUALLY, you must enter your security code + 6 +
zone number.
Any zone that was automatically bypassed by the system will be unbypassed upon
disarming the system (e.g. STAY mode, Auto-STAY, etc.).
Vent zones and zones bypassed by a programmed Auto-Bypass schedule (Tme Driven
Event) are considered "manual bypasses" and will not be unbypassed upon disarming
the system.
Zones that were in a bypassed state at the time a System Shutdown is sent from the
Compass Downloading software will be unbypassed when the System Shutdown is
removed.