Dell PowerVault NX3500 Administrator's Manual page 190

Powervault nx3500 system
Hide thumbs Also See for PowerVault NX3500:
Table of Contents

Advertisement

Workaround
190
Troubleshooting
If wrong SAN IPs are used while running the PowerVault NASCU:
Verify that the MD discovery IP used while running the
1
PowerVault NASCU is on the same subnet as one of the two SAN
IPs configured on your controllers.
To verify MD discovery IP, log in to your NAS Manger IP using
2
CLI and run the following command:
Kjd
This command shows the MD discovery IP.
If the IP is not in the same subnet as the IPs configured for your
3
SAN, change the MD discovery IP to one of the subnets defined
on your controller's SAN A and B.
If wrong IQNs are used while defining hosts in MDSM, verify that
the IQNs displayed in MDSM match the controller IQNs. To
verify the controller IQNs:
Compare if the iqns displayed in MDSM are the same as the ones
1
under the Mappings tab in the hosts section in the NAS Manager.
If there is a mismatch, correct the IQNs used for the hosts in
2
MDSM and try formatting the system. The LUNs must be
discovered and formatted.
If the issue is due to uneven number of LUNs:
If an error is encountered, verify that even number of LUNs are
1
mapped to the host group. An odd number of LUNs is not
supported. LUNs have to grow in pairs starting from 2 to 16.
If uneven LUNs are used, correct the count by adding or removing
2
a LUN.
Try to format the system.
3
If the LUN size is below minimum requirements:
Verify that the LUNs are larger than the minimum required size of
1
125 GB.
If the LUNs are less than 125 GB, change LUN size to meet or
2
exceed the minimum required size.
Try to format the system.
3