Fujitsu PRIMERGY BX600 S2 Operating Manual page 23

Fujitsu server user manual
Table of Contents

Advertisement

Important Notes
Make sure that the PRIMERGY BX600 S2 basic unit is connected to
the mains for at least one minute before pressing the power ON/OFF
button to switch the system ON.
V
CAUTION!
The server automatically adjusts to a mains voltage of 200 - 240 V.
The server may only be put into operation if the mains voltage range
set on the server corresponds to the local mains voltage.
This device has safety-tested power cables and must only be
connected to properly grounded power sockets or CEE sockets.
The power button does not disconnect the device from the mains
voltage. To completely disconnect it from the mains voltage, the
power plugs must be removed from the power socket.
Data transmission cables must not be connected or disconnected
during a thunderstorm (lightning hazard).
Make sure that no objects (such as bracelets or paper clips) or liquids
fall/spill into the device (risk of electric shock or short circuit).
Data cables must be adequately shielded to avoid interference.
The LAN wiring must comply with the standards EN 50173 and EN
50174-1/2. The minimum requirement is a protected LAN line of
category 5 for 10/100 MBps Ethernet, and/or of category 5e for
Gigabit Ethernet. The requirements of the specification ISO/IEC
11801 must be observed.
In an emergency (e.g. damage to housing, control elements or
cables, the ingress of liquids or foreign bodies), switch the unit off
immediately, pull the power plug out of the grounding outlet or the
CEE outlet, and contact Service.
Proper operation of the device (in accordance with IEC 60950/DIN
EN 60950) is only ensured if the casing is completely assembled and
the dummy units for the installation openings have been put in place
(electric shock, cooling, fire protection, interference suppression).
Install only system extensions that satisfy the requirements and rules
governing safety and electromagnetic compatibility and relating to
telecommunications terminal equipment. If you install other exten-
sions, you may damage the system or violate the safety regulations
PRIMERGY BX600 S2 Basic Unit
Notes on Safety
23

Advertisement

Table of Contents
loading

Table of Contents