Sony PDW-F800 Operation Manual page 268

Professional disc camcorder
Hide thumbs Also See for PDW-F800:
Table of Contents

Advertisement

SUB Clip NG The In and Out point positions are
invalid. Set correct In and Out
points.
MAX# SB
The total number of sub clips is
CLP
over the upper limit (300).
Resolution
An attempt was made to register a
clip in a clip list with a different
resolution.
CL OVER
The total duration of sub clips in
DUR
the current clip list is over the
upper limit (24 hours).
FAN Stopped
The main unit or drive fan has
DR-FAN Stop
stopped. Avoid use under high
temperatures, turn off the power,
and contact a Sony service
representative.
NVRAM NG! An error was detected while
accessing internal memory. Power
the unit off and contact a Sony
service representative.
Update Err!
A firmware update failed. Power
the unit off and contact a Sony
service representative.
Unknown
An unsupported USB device was
USB
connected to this unit.
NO USB
A USB flash drive write operation
MEMORY!
was attempted with no USB flash
drive connected.
USB
A write inhibited USB flash drive
MEMORY
was connected with MEMORY
INHIBIT!
REC on the MEMORY REC page
USB M. INHI
of the OPERATION menu set to
ENABL.
USB
The connected USB flash drive
MEMORY
was not usable when a USB flash
ERROR!
drive write operation was
attempted.
M. Shortage
A USB flash drive write operation
was attempted without enough
free memory in the USB flash
drive.
USB
A USB flash drive write operation
MEMORY
was attempted without free
FULL!
memory in the USB flash drive.
MEM REC
A USB flash drive write operation
NG!
failed with MEMORY REC on the
MEMORY REC page of the
OPERATION menu set to
ENABL.
268
Operation Warnings
M. access!
An attempt was made to switch
GUI screens during a USB flash
drive write operation.
Alarm messages during thumbnail
search, scene selection, and clip list
operations
An alarm message may appear in the LCD
monitor during thumbnail search, scene selection,
and clip list operations. In that case, take the
action indicated in the following table.
Cannot
The clip cannot be expanded into
Expand Clip
more blocks. This alarm appears
any Further.
when the DISP SEL/EXPAND
button is pressed when the number
of blocks is maximum, or when
the duration of an expanded
thumbnail is one frame.
Selected
The selected essence mark does
Essence Mark
not exist.
Does not
This alarm appears in the essence
Exist.
mark selection screen when the
specified essence mark does not
exist on the disc.
Sub Clip is
The temporal relationship between
Invalid. Set
the specified In and Out points in a
Appropriate
TRIM operation (see page 135) is
IN/OUT
not correct. Reset so that the value
Points.
of the Out point timecode is larger
than the value of the In point
timecode.
Duration of
The total duration of the current
One Clip List
clip list exceeds the upper limit of
must be Less
24 hours as the result of an Add
than 24
Sub Clips (see page 133) or Trim
Hours.
Sub Clip (see page 135) operation.
No More Sub
The total number of the sub clips
Clips can be
of the current clip list exceeds the
Added to the
upper limit of 300 as the result of
Clip List.
an Add Sub Clips (see page 133)
or Trim Sub Clip (see page 135)
operation.
Sub Clip does
An attempt is made to execute a
not Exist.
Move Sub Clips (see page 135),
Trim Sub Clip (see page 135),
Delete Sub Clips (see page 136),
or Set Start Time Code (see
page 136) operation with no sub
clips in the current clip list.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdw-700

Table of Contents