Vmf Setting Items - Sony Ipela SNC-RS86N User Manual

User manual (rh-rs users guide)
Hide thumbs Also See for Ipela SNC-RS86N:
Table of Contents

Advertisement

VMF setting items

Up to three VMF settings (package number1 to 3) can be
retained for each current camera position and preset
position. You can select one of those settings for use.
You can configure the inspection method and the size
and speed of object to inspect individually for each
package number.
Number of filters
Select the setting number to set from 1, 2 or 3.
The following VMF setting is saved for the individual
setting number selected here.
The set of the setting numbers selected here is valid for
current VMF setting.
Note
package1, package2 and package3 of the VMF setting
cannot be simultaneously enabled.
Filter type
Specify the VMF inspection method.
Select the inspection method from When any occur or
When all occur in order.
When any occur: An alarm will be set off when any one
of the three conditions is met.
When all occurs in order: An alarm will be set off
when the three conditions are met in the sequence
specified. If the conditions occur in an order different
from the sequence specified, such as 1, 3 and then 2,
there will be no alarm.
Each inspection method can include up to 3 criteria.
Select the inspection method from Pass, Presence,
Appear, Disappear, Volume and None.
98
Setting the Sensor input/Camera tampering detection/Motion detection/Audio detection — Event detection menu
Enable/Disable checkbox for filter
Set enable/disable for individual inspection methods.
Filter order switching button
Clicking
switches the order of inspection methods
between the neighouring methods.
e.g., If you click the button between 1 and 2, they will
switch order. If you click the button between 2 and 3,
they will switch order.
Specifying the time for "When all occurs in
order"
Specify the reference interval in seconds between 1 and
2, or 2 and 3.
For example, if 1 and 2 are set and "3 seconds" is
specified, an alarm will be set off when the inspection
conditions of 2 are met within 3 seconds from when the
inspection conditions of 1 are met.
VMF status indicator
x
The indicator is on when the set filter type conditions are
met.
Filter settings
Settings for each inspection method can be edited here.
The inspection line and active window are set to default
values. Edit according to use.
VMF status indicator of each filter
x
The filter is on when the set filter type conditions
(Passing, Existing, Appearance, Disappearance,
Capacity) are met.
Tip
The buttons displayed on the edit screen for inspection
method is used in the same way as those for detection
setting. See page 96.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents