Sequence number: A sequential number of 10 digits
between 0000000001 and 4294967295 and a
sequential 2-digit number are added to the image file
name.
Tip
A sequential number added to Date & time and
Sequence number is used to identify individual files
created with consecutive alarm events.
Sequence number clear
Click Clear to reset the Sequence number suffix to 1.
Alarm
Select the alarm to be linked with the file to be
forwarded to the FTP server.
Sensor input 1: The external sensor that is connected to
sensor input 1 of the camera I/O port.
Sensor input 2: The external sensor that is connected to
sensor input 2 of the camera I/O port.
Sensor input 3: The external sensor that is connected to
sensor input 3 of the camera I/O port.
Sensor input 4: The external sensor that is connected to
sensor input 4 of the camera I/O port.
Tampering: An alarm that is triggered when the camera
detects tampering, such as direction shift or spraying.
VMF: An alarm of the VMF detection function.
Motion detection: The alarm detected by the motion
detection function.
Click Detection, and the Motion detection menu is
displayed to allow you to set the motion detection
function (page 94).
Audio detection: Select the preset position linked with
alarm by audio detection function.
Click Detection, and the audio detection menu is
displayed to allow you to set the audio detection
function (page 94).
Note
In the case that the synchronized preset position is
specified in Position at alarm in the Preset position
menu, an alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always: Alarm detection is always effective.
Schedule: You can specify the period during which
alarm detection is effective.
Click Schedule and the menu for the effective period
is displayed. ("Setting the Schedule — Schedule
Menu" on page 93)
80
Sending Images to FTP Server — FTP client Menu
Alarm buffer
Select Use alarm buffer to forward the image/audio at
a specified time before or after alarm detection (pre-
alarm, post-alarm).
If you do not select the alarm buffer, only the image at
the moment of alarm detection is forwarded.
Click Alarm buffer to display the Alarm buffer menu.
For details, see "Setting the Alarm Buffer — Alarm
buffer Menu" on page 93.
OK/Cancel
See "Buttons common to every menu" on page 34.
Periodical sending Tab — Setting
the periodical FTP client activity
You can set to send image files (JPEG files) to an FTP
server periodically.
Periodical sending
Select On when you want to use periodical sending.
Remote path
Type the remote path using up to 64 characters.
Image file name
Type the file name of the image sent to the FTP server
using up to 10 alphanumeric characters, - (hyphen) and
_ (under score).
The actual image file name will be the specified image
file name with a suffix and extension .jpg.
Note
You cannot send an audio file using periodical sending
of the FTP client function.
Suffix
Select a suffix to be added to the file name sent to the
FTP server.
None: The name of the sent file will be the image file
name.