Figure 21
2. Select the proper classification from the RAPIDS Classification Override drop-down menu.
CAUTION: Changing the controller's classification within the AirWave UI will push a reclassification message to all controllers
managed by the AirWave server that are in Groups with Offloading the WMS database set to Yes. To reset the controller
classification of a rogue device on AirWave, change the controller classification on the AirWave UI to unclassified.
Controller classification can also be updated from RAPIDS > List via the Modify Devices link.
All rogue devices will be set to a default controller classification of unclassified when WMS is first offloaded
except for devices classified as valid. Rogue devices classified in ArubaOS as valid will also be classified within
AirWave as valid for their controller classification as well. As APs report subsequent classification information
about rogues, this classification will be reflected within AirWave UI and propagated to controllers that AirWave
manages. The device classification reflected in the controller's UI and in the AirWave UI will probably not match,
because the controller/APs do not reclassify rogue devices frequently.
To update a group of devices' controller classification to match the ArubaOS device classification, navigate to
RAPIDS > List and utilize the Modify Devices checkbox combined with the multiple sorting a filtering features.
Table 5
AMP
Unclassified (default state)
Valid
Contained
1. Navigate to the Users > User Detail page for the user.
2. Select the proper classification from the Classification drop-down menu as seen in
Figure 22
28 | Dell PowerConnect W-Series Specific Capabilities in AirWave
Rogue Detail Page Illustration
ARM to AMP Classification Matrix
User Classification
AOS (ARM)
Unknown
Valid
DOS
Dell PowerConnect W-AirWave 7.5 | Best Practices Guide
Figure