5.2.6.
Checking.the.drives.for.data.consistency
You can check and verify the accuracy of data redundancy in the selected logical
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the Objects > Adapter
menu.
The Check.Consistency command is available only for logical drives included
in a RAID 1 set.
Using.the.Check.Consistency
To check data consistency using the Check.Consistency command:
1.
From the Management.Menu, select Check.Consistency, then press
<Enter>.
2.
The screen displays the available RAID set(s) and prompts you to select the
logical drive to check. Press the <Spacebar> to select the logical drive from
the Logical.Drive selection, then press <F10>.