Safety Label - Regency U31-NG3 Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

This is a copy of the labels that accompany
each U31-3Gas Insert. We have printed a copy
of the contents here for your review. The safety
label is located on a plate inside the base of the
unit visible when the bottom louver is opened.
4001172
Minimum Clearances to Combustibles from Insert
Side wall
Ceiling
Alcove Width
Max. Alcove Depth L
NOTE: for Zero Clearance Kit clearances to
Combustibles. See manual for details.
MADE IN CANADA / FABRIQUE AU CANADA
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or
Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable,
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless
all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1,
National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou
d'autres combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par
l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz, Less than 10A
VENTED GAS FIREPLACE HEATER -
GAZ À ÉVACUATION -
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery back up in the same room where the gas appliance is installed.
Regency U31-3 Gas Fireplace Insert
NOTE: FPI units are constantly being im-
proved. Check the label on the unit
and if there is a difference, the label
on the unit is the correct one.
Listed:
VENTED GAS FIREPLACE HEATER
/
FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
é
Tested to:
Tested to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2009/CSA 2.33-2009
NATURAL GAS FIREPLACE INSERT:
Min. supply pressure
5"
Low Setting Man. pressure
1.6"
Max. Manifold pressure
3.5"
Orifice size
37
Minimum input
20,600
Altitude
0-2000ft
Maximum input
30,000
Use Conversion Kit (Part #400-970)
Min. supply pressure
5"
Low Setting Man. pressure
1.6"
Max. Manifold pressure
3.5"
Orifice size
40
Minimum input
19,200
Altitude
2000-4500ft
Maximum input
27,200
A
10"(255mm)
B
47-1/2"(1205mm)
K
48"(1220mm)
36"(915mm)
FPI Fireplace Products International Ltd.
Delta BC, CANADA
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
400
Duplicate Serial number
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ETIQUETTE
CANADA and U.S.A.
400
PROPANE FIREPLACE INSERT:
MODEL U31-NG3
Factory Equipped For Altitude 0-2000ft. (0-610m)
WC
(1.25kPa)
12"
WC
(0.40kPa)
6.4"
WC
(0.87kPa)
10"
DMS
(2.64mm)
52
Btu/h
(6.04kW)
22,000
(0-610m)
0-2000ft
Btu/h
(8.79kW)
28,000
Field Convertible For Altitude 2000-4500ft.(610-1370m)
Use Conversion Kit (Part #400-971)
WC
(1.25 kPa)
1
2"
WC
(0.40kPa)
6.4"
WC
(0.87kPa)
10"
DMS
(2.49 mm)
53
Btu/h
(5.62kW)
20,000
(610-1370m)
2000-4500ft
Btu/h
(7.97kW)
25,000
Mantel Clearances in Masonry
Fireplace Installation
B
Max. Mantel depth M 12"(305mm)
M
Mantel height
Mantel depth
L
Mantel height
N
Floor
O
Mantel Clearances in Zero Clearance
A
P
Kit Installations
Max. Mantel depth M 12"(305mm)
Q
Mantel height
R
K
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
Fan Part # 911-071
NOT FOR USE WITH SOLID FUELS. /
Serial No. / No de serie
MODEL U31-LP3
WC
(2.99 kPa)
WC
(1.59 kPa)
WC
(2.49 kPa)
DMS
(1.6mm)
Btu/h
(6.45kW)
(0-610m)
Btu/h
(8.21kW)
WC
(2.99 kPa)
WC
(1.59 kPa)
WC
(2.49 kPa)
DMS
(1.5mm)
Btu/h
(5.86 kW)
(610-1370m)
Btu/h
(7.33 kW)
N
17"(432mm)
O
3-1/2"(89mm)
P
13"(330mm)
Q
19-1/2"(495mm)
N 22"(432mm)
FOYER AU
919-098
5