Download Print this page

Regency U32-LP5 Specification Sheet

Gas insert
Hide thumbs Also See for U32-LP5:

Advertisement

U32 Regency Gas Insert
Model
Fuel Type
Minimum Supply Pressure
5" W.C. (1.25 kPa)
Manifold Pressure - High
3.8" W.C. (0.95 kPa)
Manifold Pressure - Low
1.1" W.C. (0.27 kPa)
Orifi ce Size -Altitude 0-4500 ft.
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Approved Venting Systems
Flex Vent Systems:
B
H
D
Dimension Description
A
Faceplate Width
B
Faceplate Height
C
Unit Width
D
Unit Height
E
Unit Depth
F
Faceplate to Vent Centerline
G
Faceplate Depth
H
Height to Vent Collar
I
Optional or Standard Front Depth
August 2008 Product Specifi cations Book
Gas Inserts
U32 Regency Gas Insert
U32-NG5
U32-LP5
Natural Gas
Propane
12" W.C. (2.99 kPa)
11" W.C. (2.74 kPa)
2.9" W.C. (0.72 kPa)
#37 DMS
#52 DMS
15,300 BTU/h
15,000 BTU/h
(4.48 kW)
(4.40 kW)
30,000 BTU/h
30,000 BTU/h
(8.79 kW)
(8.79 kW)
3" Co-linear
3" Co-linear
FPI AstroCap™ Flex Vent
A
C
G
I
F
E
U32
40-1/4" (1022mm)
26-1/4" (667mm)
28" (711mm)
20" (508mm)
13-3/4" (349mm)
10-3/4" (273mm)
1-3/8" (35mm)
21-1/16" (535mm)
3-3/4" (95mm)

Minimum Fireplace Dimensions

The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
M
J
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
Dimension Description
J
Height
K
Width
L
Depth
M
Max. Lintel Bar Depth
N
Rear Width
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
L
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
K
N
Contour
Molded
Faceplate
Faceplate
22" (559mm)
22" (559mm)
26-1/2" (673mm)
29" (737mm)
14" (356mm)
15" (381mm)
9" (229mm)
10" (254mm)
22-1/2" (572mm)
22-1/2" (572mm)
125

Advertisement

loading
Need help?

Need help?

Do you have a question about the U32-LP5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency U32-LP5

  • Page 1: Minimum Fireplace Dimensions

    Gas Inserts U32 Regency Gas Insert Model U32-NG5 Fuel Type Natural Gas Minimum Supply Pressure 5” W.C. (1.25 kPa) Manifold Pressure - High 3.8” W.C. (0.95 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) Orifi ce Size -Altitude 0-4500 ft.
  • Page 2: Combustible Mantels

    U32 Regency Gas Insert Clearances Unless otherwise stated the clearances listed below are Minimum distances to combustible materials. Please Note: A major cause of chimney related fi res is due to a failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi...

This manual is also suitable for:

U32-ng5U32