Owners & U31 Gas Insert Energy ™ Installation Manual U31 Video www.regency-fire.com MODELS: U31-NG10 Natural Gas U31-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2
Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your FPI Fireplace. U31 Video Regency U31-10 Gas Fireplace Insert...
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency U31-10 Gas Fireplace Insert...
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency U31-10 Gas Fireplace Insert...
ALERTED TO THE HAZARDS OF HIGH IF THE BARRIER BECOMES DAMAGED, SURFACE TEMPERATURES, ESPE- THE BARRIER SHALL BE REPLACED CIALLY THE FIREPLACE GLASS, AND WITH THE MANUFACTURER'S BARRIER SHOULD STAY AWAY TO AVOID BURNS FOR THIS APPLIANCE. OR CLOTHING IGNITION. Regency U31-10 Gas Fireplace Insert...
BURNING FIREPLACE SAVE THESE INSTRUCTIONS REQUIREMENTS FACTORY BUILT FIREPLACE The Regency Gas Insert must be installed in accordance with these instructions. Carefully NOTE: Any parts that are removed must be removed The U31-10 Gas Inserts have been tested and read all the instructions in this manual first.
CHECKLIST 1. The appliance installation must conform with local codes or in the absence of local codes, The Regency Gas Insert is installed as listed below. with CAN/CGA B149 (in Canada) or the National Fuel Gas Code ANSI Z223.1. This 1.
Max. Mantel Depth G 12" / 305 mm Min. Alcove Width K 48" / 1220 mm Max. Alcove Depth L 36" / 915 mm * No Hearth Required Standard Faceplate 8-1/8 ” Low pro le Regency U31-10 Gas Fireplace Insert...
COMBUSTIBLE MANTEL CLEARANCES IN MASONRY INSTALLATION Clearances for Standard Faceplate / Clearances for Low Profile Faceplate with Safety Screen Contour Faceplate with Safety Screen 12 | Regency U31-10 Gas Fireplace Insert...
Burner grip the wrench by the short side. Orifice 19) Replace Burner Tray and reverse steps 5) to 20) Adjust the burner aeration setting to 3/8" to 3/8" as required for the best flame picture. Regency U31-10 Gas Fireplace Insert...
Propane 10" w.c. The Regency Insert incorporates its own internal The manifold pressure is controlled by a regulator draft hood, so no additional external draft hood built into the gas control, and should be checked at is required.
The thermally actuated safety switch will auto- matically reset after it has cooled off. The switch will continue to cycle until the draft problem is corrected. DO NOT BYPASS OR DISCONNECT Diagram 3 THIS SWITCH. Regency U31-10 Gas Fireplace Insert...
2) Sprinkle the vermiculite around the fi rebox base. Take some of the embers (approx. 1/3 of the bag) and B)02-45 sprinkle over the vermiculite. 16 | Regency U31-10 Gas Fireplace Insert 908-783a Page 1 of 3 03/30/09...
Page 17
E)02-47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner. Notch D)02-46 F)02-48 A)02-43 C)02-56 Bracket B)02-45 Cutout 908-783a 03/30/09 Page 2 of 3 Regency U31-10 Gas Fireplace Insert...
Page 18
A) 02-43 D) 02-46 G)02-44 F) 02-47 E) 02-45 B) 02-56 C) 02-44 The "02" refer numbers (i.e. 02-43) are molded into the rear of each log. 908-783a Page 3 of 3 03/30/09 18 | Regency U31-10 Gas Fireplace Insert...
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Regency U31-10 Gas Fireplace Insert...
4 remaining black screws. switches with the notch on the left side panel. Diagram 5. 10. Push the Regency logo plate into the two holes in the bottom left corner of the face- plate. 20 |...
The use of substitute glass will void all product warranties. Do not operate the appliance if the glass panel(s) are removed, cracked or broken. Replacement of the glass panel(s) should be done by a qualified service person. Regency U31-10 Gas Fireplace Insert...
Attach the clip to the rear of the faceplate to en- sure that the wires do not touch the side of the unit. The power cord should be run behind the inner faceplate panel. Diagram 7 Diagram 4 02/16/15 919-524 22 | Regency U31-10 Gas Fireplace Insert...
Page 23
Diagram 8 Bracket Inner faceplate panel pins Attach Regency logo to bottom louver. Install bottom louver by hanging louver on brackets installed in step 8. Diagram 11 11) Install safety screen–see next page. Diagram 9 Attach Regency logo to left...
2. Hook the tabs on the safety screen into the slots on the unit. 3. To remove–lift screen assembly up and pull away from unit. 24 | Regency U31-10 Gas Fireplace Insert...
15 min. to stabilize. CAUTION Any alteration to the product that causes soot- ing or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer. Regency U31-10 Gas Fireplace Insert...
Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process. ON/OFF Button Diagram 2 26 | Regency U31-10 Gas Fireplace Insert...
"OFF". Mettre le bouton de commande de gaz en position OFF pour éteindre la veil- leuse. Pour économiser le carburant, éteignez la veilleuse quand l’appareil reste longtemps inutilisé. 919-525 DO NOT REMOVE THIS INSTRUCTION PLATE Regency U31-10 Gas Fireplace Insert...
Your Regency insert is supplied with high tem- cleaned. Replace the embers but do not block ment log. The position of these logs must be as perature, 5 mm Neoceram ceramic glass that will the pilot.
Burner Tray to the left, and lift off. Aeration Adjustment Rod 8. Remove the 12 screws holding the Access Panel in place. 9. Remove the Fan Air Duct by removing 4 screws, 2 per side. Regency U31-10 Gas Fireplace Insert...
3/4" Rope Gasket Strain Relief Grommet for power cord 404-969 Conversion to LP Kit 404-015 Air Channel 919-435 Manual 402-920 Flush Louvers (Set) - Black *Not available as a replacement part. 405-929 Safety Screen Assembly 30 | Regency U31-10 Gas Fireplace Insert...
Page 31
Remote Transmitter GTMF (Hand Held) 910-572 Remote Receiver 911-137 Remote Receiver Battery Compartment Door 911-164 Valve/Remote Wiring Harness 910-036 Pilot Oridice - NG 910-037 Pilot Orifice - LP 910-341 Thermopile 910-386 Thermocouple *Not available as a replacement part. Regency U31-10 Gas Fireplace Insert...
Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid- ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
Page 36
Register your Regency warranty online ® www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.