Regency Ultimate U1500E ™ Owners & Installation Manual Gas Fireplace 500E MODELS: -NG Natural Gas 500E -LP Propane www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH, in Canada. Regency Ultimate ™ U1500E Gas Fireplace...
Page 3
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The U1500E has been designed to provide ® you with all the warmth and charm of a fireplace at the flick of a switch. The model U1500E has been approved by Warnock Hersey/Intertek for both safety and efficiency.
Valve Tray Replacement ..........55 Venting Arrangement for Vertical Terminations ....28 Parts Unit Installation with Horizontal Termination ....31 5" x 8" venting ..............31 Main Assembly ............56 Unit installation with Vertical Termination .....32 Accessories ..............58 Warranty Warranty ..............60 Regency Ultimate ™ U1500E Gas Fireplace...
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency Ultimate ™ U1500E Gas Fireplace...
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Ultimate ™ U1500E Gas Fireplace...
UNIT DIMENSIONS 54-5/16" (1381mm) 49-11/16" (1263mm) 8" 5" 49-11/16" (1263mm) 45-1/4" (1150mm) ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency Ultimate ™ U1500E Gas Fireplace...
National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3. See general construction and assembly instructions. The appliance and vent should be enclosed. Regency Ultimate ™ U1500E Gas Fireplace...
Flat on Wall Corner Recessed into Wall/Alcove 14. Final check. Corner Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer. Regency Ultimate ™ U1500E Gas Fireplace...
Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Alcove Regency Ultimate ™ U1500E Gas Fireplace...
Top of Fireplace From base of unit Opening MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 3-1/4" (83mm) Non-Combustible MANTEL LEG 1.5" (38mm) 7-1/8” (181mm) Allowable mantel leg projection 10”(203mm) 13”( 279mm) Regency Ultimate ™ U1500E Gas Fireplace...
2) Easier access to gas connection with panel removed. 3) Install any optional components with access panel removed. 4) Reinstall access panel with 4 screws Note: Access panel is no longer usable once facing material installed. Installation Access Panel Regency Ultimate ™ U1500E Gas Fireplace...
See non combustible section in this manual for details. Drywall or other facing Header Pipe heatshield. See manual for details. Non-combustible header (steel stud on edge) Note: All other framing may Non-Combustible be of wood construction. Facing Finished Floor Regency Ultimate ™ U1500E Gas Fireplace...
Secure the end of the extender to framing/ wall. Deflector extender--secure to framing/wall. 5. If there is any excess material on the horizontal section of the deflector, it can be folded down at the fold lines. Regency Ultimate ™ U1500E Gas Fireplace...
6 screws (2 at bottom, 2 at top and 2 on sides) as shown. NOTE: Ensure the flat side of the steel stud is facing the wood framing. Horizontal stud (606-067)A 7 03 A Large stud (606-066)A Large stud (606-066)A Regency Ultimate ™ U1500E Gas Fireplace 919-807 08.21.17...
11. Using the two (2) screws provided secure the cover plate to the Battery Holder. 12. For coding instructions, see full details in this manual. Low Voltage Junction Box Proflame Battery Holder J-Box Battery Holder Slider Switch Wall Plate Diagram 1 Regency Ultimate ™ U1500E Gas Fireplace...
6. Prime wall for a second time for proper adhesion of paint 7. Paint walls using a high quality paint which will withstand the high temperatures being emitted from this appliance. Non-combustible board-faces and edges MUST BE PRIMED. Regency Ultimate ™ U1500E Gas Fireplace...
1-1/2" as shown in the diagram below. The faceplate will not be able to be mounted if finished material is beyond 1-1/2". Ensure front of facing material is flush with the edge of the flange on the fireplace. Regency Ultimate ™ U1500E Gas Fireplace...
Page 20
While every precaution is taken in providing the recommendations on preparation and finish, given the variations in paint quality, with temperature limits and workmanship in application, Regency is unable to guarantee the life of the joint compounds, paint or any other finish materials or workmanship applied to or used in any application surrounding the fireplace.
* Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Ultimate ™ U1500E Gas Fireplace...
4. Adjust the vent restrictor plate to the required vent restrictor position as (factory setting) per the diagrams shown below. restrictor plate not installed 5. Once the vent restrictor plate is in the required position, secure with screws. Regency Ultimate ™ U1500E Gas Fireplace...
Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
Page 25
1 foot of run towards the termination. 36” (914mm) 29-13/16” (757mm) 39-7/16” (1002mm) Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Ultimate ™ U1500E Gas Fireplace...
Intertek WHI listing of these components. The Regency AstroCap and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as any specific chimney systems listed in this manual. AstroCap is a proprietary trademark of Regency Fireplace Products.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
• Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required. Set2-1-1/8"open Set1-1-5/8"open Regency Ultimate ™ U1500E Gas Fireplace...
Page 29
Please note min. 1 5' Min. 6' Max 8' Min. foot between 90 elbows is required. 6' Min. 7' Max 9' Min. 7' Min. 8' Max 10' Min. Restrictor Set 0 - 5" Factory Setting Regency Ultimate ™ U1500E Gas Fireplace...
Page 30
4' Max. 10' Min. 7' Max. foot between 90 elbows is required. 6' Min. 5' Max. 11' Min. 8' Max. 7' Min. 6' Max. 12' Min. 9' Max. Restrictor Set 0 - 5" Factory Setting Regency Ultimate ™ U1500E Gas Fireplace...
10. Install wall thimble in the center of the framed hole and attach with wood screws (Diagram Diagram 1 Diagram 4 Diagram 2 IMPORTANT Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications. Regency Ultimate ™ U1500E Gas Fireplace...
Important: Always check for gas leaks with a roof lines, in these cases, increasing the soap and water solution or gas leak detector. vent height may solve the problem. Do not use open flame for leak testing. Regency Ultimate ™ U1500E Gas Fireplace...
6. When finished reading manometer, turn off the unit, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten. Regency Ultimate ™ U1500E Gas Fireplace...
Page 34
2 below. 9. Unscrew the pilot orifi ce with the Allen key and replace with the LP- pilot orifi ce in the kit and replace pilot cap (see below). Diagram 2--Screw Locations 06.21.17 919-794 Regency Ultimate ™ U1500E Gas Fireplace...
Page 35
(NG) to the rearward position (opening closer to the back wall of the unit) (LP) as shown below. Secure the pins in the new location using the same pins and screws removed. 919-794 06.21.17 Regency Ultimate ™ U1500E Gas Fireplace...
DISCONNECT POWER SUPPLY TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Ultimate ™ U1500E Gas Fireplace...
Diagram 5 Log 2 should perfectly t into this space 4. Line up locator on Log 3 with corresponding locator on Ceramic Log Burner as shown in Diagram 6. Diagram 3 Diagram 6 Regency Ultimate ™ U1500E Gas Fireplace 05/29/17 919-587a...
Page 39
Position of Log 5 8. Log 7 in fi nal position shown in Diagram 12. Diagram 8 The Arch on Log 5 should rest on the Arch on Log 1. Diagram 12 Diagram 9 Regency Ultimate ™ U1500E Gas Fireplace 919-587a 05/29/17...
1. Remove front trim piece - see instructions above. 2. Remove two (2) screws in locations shown below to release panel clips. Panel Clip 3. Remove panels by sliding out. Panel Clip Screw Locations 4. Reverse steps to reinstall. Regency Ultimate ™ U1500E Gas Fireplace...
Note: Bottom of frame is secured to glass door frame with left and right magnets. 3. Hook the inner door frame (3) and safety screen assembly (2) over the inner door trim. 06.21.17 919-796 Regency Ultimate ™ U1500E Gas Fireplace...
4. Remove any finger prints/ marks prior to operating the unit. WARNING: Turn off the unit by way of the wall switch or remote. Allow unit to cool at least 10 min. - prior to remov- ing the faceplate. Diagram 3 Regency Ultimate ™ U1500E Gas Fireplace 06.21.17 919-795...
1. Install the optional finishing trim by lining up trim with the outside of the fascia. Press trim inward firmly to seat onto the unit. tooltip Finishing Trim Installed 2. Pull trim outward–away from the unit to remove. 06.27.17 919-806 Regency Ultimate ™ U1500E Gas Fireplace...
6. Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned. 7. The unit should never be turned off, and on again without a minimum of a 60 second wait. Regency Ultimate ™ U1500E Gas Fireplace...
Manual mode: Fan will turn on and off immediately using the remote control transmitter if the fan function is in the "on" position. Continuous Pilot/Intermittent Pilot (CPI/IPI) selection See remote control instructions for details. Note: Remote may not be exactly as shown. Regency Ultimate ™ U1500E Gas Fireplace...
If service is to be performed–you must disconnect power and shut off gas to the unit. Appuyer sur la touche ON/OFF de la télécommande. En cas d'entretien, vous devez débrancher l'alimentation et couper le gaz alimentant l'unité. DO NOT REMOVE THIS INSTRUCTION PLATE 919-634 Regency Ultimate ™ U1500E Gas Fireplace...
(*) The receiver may be independent or integral to the IFC hearth ap- pliance control module. The receiver instruction may not be indepen- dent when part of the IFC. Figure 2: Transmitter LCD Display Fig3: Battery Figure 3: Battery Compartment compartment. Regency Ultimate ™ U1500E Gas Fireplace 09.29.17 919-829...
Page 48
Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confi rms reception of the command. Figure 9 Figure 10 Regency Ultimate ™ U1500E Gas Fireplace 919-829 09.29.17...
Keys (fi g.1) to turn on, off or adjust the fan speed (fi g. 14). A single “beep” will confi rm reception of the command. Figure 17 Figure 18 Figure 13 Figure 14 Regency Ultimate ™ U1500E Gas Fireplace 919-829 09.29.17...
When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Fig. 22) before all battery power is lost. When the batteries are replaced this Icon will disappear. Figure 22 Regency Ultimate ™ U1500E Gas Fireplace 919-829 09.29.17...
ANCE AND TO REPLACE ANY aged. PART OF CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS Top View of pilot flame BEEN UNDER WATER. 10. Verify operation after servicing. Regency Ultimate ™ U1500E Gas Fireplace...
CAUTION: Wear gloves when removing damaged or broken glass. WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person. Regency Ultimate ™ U1500E Gas Fireplace...
6. Pull the bottom of the door towards you until the door is angled away from the firebox by about 30°. Lift the door up and over the upper door hooks. 7. To install the glass door - reverse steps. Regency Ultimate ™ U1500E Gas Fireplace...
Round Magnet 1/2 inch x 1/8 inch (Each) N/S 904-970 Cup Magnet 1/2 inch x 5/8 inch OD (Each) N/S 676-900 Steel Stud Framing Pkgd U1500E N/S 676-969 Conversion - LP U1500E N/S 676-936 Non combustible board Regency Ultimate ™ U1500E Gas Fireplace...
Page 59
Regency Ultimate ™ U1500E Gas Fireplace...
FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: December 2016 Regency Gas Products Warranty Regency Ultimate ™ U1500E Gas Fireplace...
Page 61
Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: December 2016 Regency Gas Products Warranty Regency Ultimate ™ U1500E Gas Fireplace...
Page 62
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
Page 63
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
Page 65
Regency Ultimate ™ U1500E Gas Fireplace...
Page 66
Regency Ultimate ™ U1500E Gas Fireplace...