Frymaster Ultimate Electric Series Service & Parts Manual page 10

Frymaster ultimate electric series fryers service & partsmanual
Table of Contents

Advertisement

1.5 Replace Temperature Probe (cont.)
10. Thread the new probe wire through the hole
in tilt plate. Place the new temperature probe
assembly onto the element and secure with
the bracket and screws removed earlier. Clip
the probe onto the rear of the element (arrow)
in two places. The temperature probe
assembly should be oriented in the same
manner as the probe being replaced.
11. Thread the probe wires into the harness
insulation. Note the pin positions and insert
pins in the connector. Reconnect the harness
and secure with a wire-tie.
12. Lower the element into the frypot with the lift
handle.
13. Place the tilt housing cover over the tilt
housing assembly and secure with screws.
Slightly raising the elements will facilitate
tilt-housing installation.
14. Install back cover(s) and secure with screws
ULTIMATE ELECTRIC SERIES FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-5
Secure probe bulb to the element back in two places
with metal wire wrap (arrow).
Install tilt housing and cabinet backs after probe
installation is complete.