4. The burner manifold pressure should be checked at this time by the local gas company or an
authorized service agent. The tables below indicate the proper burner manifold pressures:
Table 5: CE Standard
Burner Manifold Gas Pressures
(Other than Belgium)
Gas
Natural Gas Lacq
(G20) under 20 mbar
Natural Gas Gronique
(G25) under 25 mbar
Natural Gas Gronique
(G20) under 20 mbar
Propane
(G31) under 37 or 50 mbar
5. Check the thermostat calibration or temperature programmed into the computer.
For units equipped with thermostat controls, refer to the Thermostat Calibration instructions
in Chapter 5.
For units equipped with other types of controllers, refer to the appropriate section of the
Frymaster Fryer Controllers User's Manual, provided with your equipment for instructions
on programming and operating your controller.
2.5
Converting to Another Gas Type
Your fryer is configured at the factory for either natural gas or Propane (LP) gas.
If you desire to switch from one type of gas to another, a gas conversion kit must be installed by a
Factory Authorized Service Center technician.
This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
Switching to a different type of gas without installing the proper conversion kit may
result in fire or explosion! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY
Model 35
Model 45
Pressure
Pressure
(mbar)
(mbar)
9
7,5
13,5
10
13,5
10
22,5
20,6
Table 7: Non-CE Standard
Burner Manifold Gas Pressures
Gas
Natural
LP
DANGER
components.
DANGER
FOR WHICH IT IS NOT CONFIGURED!
2-8
Table 6: CE Standard
Burner Manifold Gas Pressures
(Belgium)
Model 35
Pressure
Gas
(mbar)
Natural Gas Lacq
(G20) under 20 mbar
Natural Gas Gronique
(G25) under 25 mbar
Natural Gas Gronique
(G20) under 20 mbar
Propane
(G31) under 37 or 50 mbar
Pressure
3" W.C.
0.73 kPa
8.25" W.C.
2.5 kPa
Model 45
Pressure
(mbar)
9
7,5
9
7
9
10
22,5
20,6