Frymaster FOOTPRINT PRO SERIES 35 Installating And Operation Manual page 15

Gas fryers
Hide thumbs Also See for FOOTPRINT PRO SERIES 35:

Advertisement

4. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position.
• For fryers equipped with thermostat controls, verify that the power and heat lights are lit.
• For fryers having computer or digital displays, verify that the display indicates
c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are
out, or that the display is blank.
5. Refer to the data plate on the inside of the fryer door to verify that the fryer burner is configured
for the proper type of gas before connecting the gas line quick-disconnect device or piping from
the gas supply line.
6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables:
Table 1: CE Standard for Incoming Gas Pressures
Model
Gas Type
Pressure
1
(mbar)
Orifice
Size
Number of
Orifices
Manifold
Pressure
Air Flow
3
(m
/H)
1
(mbar) = 10,2 mm CE
7. For fryers equipped with a built-in filter system and/or basket lifts, plug the electrical cord(s) into
a power receptacle behind the fryer.
Model 35
G20
G25
G31
20
20-25
37-50
1,70
1,70
1,05
9
9
9
9
13,5
22,5
2,50
3,06
1,51
Table 2: Non-CE Standard
for Incoming Gas Pressures
Gas
Minimum
6" W.C.
Natural
1.49 kPa
14.93 mbar
11" W.C.
2.74 kPa
LP
27.37 mbar
2-5
Model 45
G20
G25
G31
20
20-25
37-50
1,40
1,40
0,86
18
18
18
7,5
10
20,6
3,10
3,58
1,80
Maximum
14" W.C.
3.48 kPa
34.84 mbar
14" W.C.
3.48 kPa
34.84 mbar