A-C68 Back Panel - Russound A-C68 Installation Manual

A-bus multizone controller
Table of Contents

Advertisement

A-C68 BACK PANEL

MUTE 12VDC TRIGGER IN - Applying 12VDC to the Mute In jack will mute all A-C68 Zones.
3.5mm PAGE INPUT - Applying audio (in a 3.5mm connector) to the Page In jack will activate audio
page for assigned A-C68 zones and initiate a page (overrides signal sense).
PAGE TRIM - Adjust the line level audio page input
KEYPAD PORTS - One A-BUS Keypad Port for each of the eight A-C68 Zones.
CONTROL LINK IN/OUT - RJ45 female jacks link multiple A-C68 controllers and pass IR, Status and two-way event driven commands between controllers.
12
COMMON IR OUTPUT - Output jack passes all IR signals from all keypads.
SOURCE IR OUTPUTS - Six source-specific IR Output
jacks allow IR control of source equipment.
AC 100/240 INPUT - Grounded 3-terminal plug detachable power cord connection,
AUDIO SOUREC LOOP OUTPUT - Buffered audio line level loop output connection
SOURCE INPUTS - Six pair of audio line level input connections for A-C68 source components.
SOURCE VOLUME TRIM - Adjust the line level audio input
12VDC TRIGGER OUT - 12VDC 100mA Trigger Out turns on when any zone is on, and turns off 5 minutes after the last zone is turned off.
Russound A-C68 Installation Manual
FUSE HOLDER - Holds a replaceable fuse for A/C input connection:
100VAC operation - T3.0A; 240VAC operation, T1.25A.
autoswitching A/C input voltage for 100 and 240VAC.