Air Conditioner Features; Electronic Control Operating Instructions - NewAir AC-12100E Owner's Manual

Portable
Hide thumbs Also See for AC-12100E:
Table of Contents

Advertisement

ELECTRONIC CONTROL OPERATING INSTRUCTIONS

Before you begin, thoroughly familiarize yourself with the control panel and remote controller
and all its functions, then follow the symbol for the functions you desire.
The unit can be controlled by the unit control panel alone or with the remote controller .
NOTE: This manual does not include remote control operation instructions.Please see the
Remote Control Operation Instructions packed with the unit for details.
OPERATION PANEL OF THE AIR CONDITIONER
(Available only on
models with auto
swing feature.)
AUTO
COOL
HEAT
DRY
FAN
Fig. 4
MODE select button
1
Selects the appropriate operating mode.
Each time you press the button, a mode
is selected in a sequence that goes from
AUTO, COOL, DRY, FAN and HEAT(except
cooling only models). The mode indicator light
illuminates under the different mode settings
2
TIMER button
Used to initiate the AUTO ON start time and
AUTO OFF stop time program, in conjunction
with the
&
buttons.
3
POWER button
Power on/off.
SLEEP button
4
Used to initiate the SLEEP function.
5
FAN button
Control the fan speed. Press to select the fan
speed in four steps-LOW, MED, HI and AUTO.
The fan speed indicator light illuminates under
different fan settings except AUTO speed. When
the auto fan speed is selected, all the fan indicator
lightsturn dark.
6
8
SWING
TIMER ON
MODE
TIMER OFF
2
1

AIR CONDITIONER FEATURES

7
6
F
C
3
6
UP(
) and DOWN(
Used to adjust (increasing/decreasing)
temperature settings(2°F/ 1°C increments)
in a range of 62°F (17°C) to 88°F (30°C)
orthe TIMER setting in a range of 0~24hrs..
NOTE: The control is capable of displaying
temperature in degrees Fahrenheit or degrees
Celsius. To convert from one to the other, press
and hold the Up and Down buttons at the same
time, for 3 seconds.
7
LED Display
Shows the set temperature in°F and°C and
the auto-timer settings.
While on DRY and FAN modes, it shows
the room temperature.
Error codes:
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
P1- Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.
6
Remote Signal Receptor
(Some models have the
signal receptor on the
front panel , Fig.2)
HI
MED
SLEEP
FAN
LOW
4
5
) buttons

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents