Ts-1000 Loop Back Test - Planet GT-906B60 User Manual

10/100/1000 base-t to 1000base-sx/lx managed media converter
Hide thumbs Also See for GT-906B60:
Table of Contents

Advertisement

4.7.3 TS-1000 Loop Back Test

The TS-1000 Loop Back Test allows manual run this loop back test to check the interconnection between two Media
Converter devices. To assure the Remote TS-1000 OAM function can work correctly.
In-band and out-band Loop back
1. Instruct center Media Converter to issue an OAM frame to request a loop back test. Terminal return start response
OAM frame to center Media Converter.
2. Terminal Media Converter runs at loop back mode.
3. Central Media Converter send test frame and terminal Media Converter loop back the frames. Test frame can be
generated from central Media Converter's UTP port (Out-Band) or from central Media Converter (In-Band)
automatically.
4. Center Media Converter check the loop back test result after sending all test frames
5. Instruct the central Media Converter to end loop back test.
This function provides TS-1000 Loop Back Test of Managed Media Converter. Press the "Apply" button to run Loop Back
Test and see the TS-1000 Loop Back Test Result of Managed Media Converter, also press the "Refresh" button to renew
the Web screen. The screen in
Managed Media Converter.
Figure 4-38
appears and
Table 4-14
describes the TS-1000 Loop Back Test object of
-47-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gt-906b15Gt-906a60Gt-902sGt-902Gt-906a15Gt-905a

Table of Contents