Checking The Serverboard Setup - Supero A+ SERVER User Manual

Table of Contents

Advertisement

A+ SERVER 2042G-TRF/6RF User's Manual
2-5

Checking the Serverboard Setup

After you install the 2042G-TRF/6RF in the rack, you will need to open the top
cover to make sure the serverboard is properly installed and all the connections
have been made.
Accessing the Inside of the System
1.
First, release the retention screws that secure the system to the rack.
2.
Grasp the two handles on either side and pull the system straight out until it
locks (you will hear a "click").
3.
Next, release the thumbscrew at the middle rear of the top cover. Then
depress the two buttons on the top of the chassis to release the top cover.
4.
Push the cover away from you (toward the rear of the chassis) until it stops.
You can then lift the top cover from the chassis to gain full access to the
inside of the server.
5.
To remove the system from the rack completely, depress the locking tabs in
the chassis rails (push the right-side tab down and the left-side tab up) to
continue to pull the system out past the locked position.
Checking the Components and Setup
1.
You may up to four processors already installed in the serverboard. Each
processor needs its own heatsink. See Chapter 5 for instructions on
processor and heatsink installation.
2.
Your server system may have come with system memory already installed.
Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
3.
If desired, you can install an add-on card to the system. See Chapter 5 for
details on installing PCI add-on cards.
4.
Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. See Chapter 5 for details on cable connections.
2-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

A+ server 2042g-trfA+ server 2042g-6rf

Table of Contents