Octuple Setting Is Selected (Cc-Link Ver.2) (C122=3) - Toshiba TOSVERT VF-S15 series Function Manual

Tosvert vf-s15 series cc-link option unit
Hide thumbs Also See for TOSVERT VF-S15 series:
Table of Contents

Advertisement

5.5.4. Octuple setting is selected (CC-Link Ver.2) (c122=3)

This option occupies one station area of the buffer memory of the PLC.
In the case of c122 = 3, there are remote I/O (RX, RY both 32 bits(same as CC-LINK
Ver.1)) and the remote register (RWw, RWr both 32 word) in the communication data for one
station area.
* Default value of RY and RX is 0.
Remote register (Default value = 0)
RWr
Address
RWr n
Monitor value 1
Monitor value 2
RWr n+1
(output frequency)
RWr n+2
Reply code
RWr n+3
Read data
RWr n+4
Monitor value 3
RWr n+5
Monitor value 4
RWr n+6
Monitor value 5
RWr n+7
Monitor value 6
Upper 8
Bits
RWr n+8
Lower 8
Bits
RWr n+9
Trip information (output frequency)
RWr n+A
Trip information (output current)
RWr n+B
Trip information (output voltage)
RWr n+C
Trip information (energization time)
RWr n+D
Reserved*
RWr n+E
Reserved*
RWr n+F
Reserved*
RWr n+10
Reply code 2
RWr n+11
Read data 2
RWr n+12
Reply code 3
RWr n+13
Read data 3
RWr n+14
Reply code 4
RWr n+15
Read data 4
RWr n+16
Reply code 5
RWr n+17
Read data 5
RWr n+18
Reply code 6
RWr n+19
Read data 6
RWr n+1A
Reserved*
RWr n+1B
Reserved*
RWr n+1C
Reserved*
RWr n+1D
Reserved*
RWr n+1E
Reserved*
RWr n+1F
Reserved*
"n" is depend on the station number.
* The bit described "
Reserved
** Do not use it.
Inverter → PLC
Signal
Trip history No.
Trip code
" is unstable. Don't use the "
RWw
Address
RWw n
Monitor code (1 and 2)
RWw n+1
Set frequency
RWw n+2
Instruction code
RWw n+3
Write data
RWw n+4
Monitor code 3
RWw n+5
Monitor code 4
RWw n+6
Monitor code 5
RWw n+7
Monitor code 6
Upper 8
Bits
RWw n+8
Lower 8
Bits
RWw n+9
Reserved**
RWw n+A
Reserved**
RWw n+B
Reserved**
RWw n+C
Reserved**
RWw n+D
Reserved**
RWw n+E
Reserved**
RWw n+F
Reserved**
RWw n+10
Instruction code 2
RWw n+11
Write data 2
RWw n+12
Instruction code 3
RWw n+13
Write data 3
RWw n+14
Instruction code 4
RWw n+15
Write data 4
RWw n+16
Instruction code 5
RWw n+17
Write data 5
RWw n+18
Instruction code 6
RWw n+19
Write data 6
RWw n+1A
Reserved**
RWw n+1B
Reserved**
RWw n+1C
Reserved**
RWw n+1D
Reserved**
RWw n+1E
Reserved**
RWw n+1F
Reserved**
" bit for the judgment.
Reserved
- 19 -
E658130
PLC → Inverter
Signal
Trip history No..
Reserved**