6.2
Troubleshooting for Electrical Errors
1) RADF does not work (except in the case of a paper jam or when the cover is open)
Interface harness connected properly?
NO→
Connect the harness properly or replace it
↓
YES
DC+5V supplied to CN70-2, 3pin?
↓
NO→
Connect the harness properly or replace it
YES
DC+24V supplied to CN70-6, 7pin?
↓
NO→
Connect the harness properly or replace it
YES
DC+24V supplied to CN72-4pin?
↓
NO→
Check or replace the jam access cover switch
YES
Empty sensor is ON when there is paper?
↓
NO→
Check or replace the empty sensor
YES
Check or replace the RADF board
2) Communication error
Interface cable normal?
↓
NO→
Replace the interface cable
YES
Check or replace the RADF board and check the equipment
3) Size detection error
Original tray sensor is ON when there is paper?
↓
NO→
Replace the sensor or harness
YES
Registration roller does not catch the original?
↓
YES→ Clean the roller with alcohol or replace
NO
Original width detection sensor-1 is ON when there is paper?
↓
NO→
Replace the sensor or harness
YES
Original width detection sensor-2 is ON when there is paper?
↓
NO→
Replace the sensor or harness
YES
Check or replace the RADF board