Configure Management Default Gateway Address

Configure Management Inband Address

4821-A2-ZN21-30
The configure management default gateway command specifies the IP
address of the next hop router for the management traffic.
configure management default-gateway {ip_address}
Minimum Access Level: Administrator
ip_address – Specifies the IP address of the default gateway for the
management ports.
Example:
PDYN# configure management default-gateway 137.90.127.1
The configure management inband address command specifies the IP
address of the unit.
configure management inband address {ip_address} { subnet_mask}
Minimum Access Level: Administrator
ip_address – Specifies the management IP address. Default is 0.0.0.0
(disabled). Do not configure inband and out-of-band management on the
same subnet.
subnet_mask – Specifies the subnet mask to be applied to the IP address.
The default mask is 255.255.255.0.
Example:
PDYN# configure management inband address 137.90.127.3
255.255.255.0