Setting Up A Scan Pattern - Avocent Outlook 180DX Installer/User Manual

Table of Contents

Advertisement

24
OutLook 180DX Installer/User Guide
To set a Delay Time for OSCAR:
1.
Highlight the Delay Time option and use the Plus ( + ) or Minus ( – ) keys
to obtain the desired value.
2.
Press Enter to save the settings and exit the menu.
To change the OSCAR display attributes:
1.
Highlight the display setting you want to change. Use the Plus ( + ) or
Minus ( – ) keys to obtain the desired value. As you select different values,
the effect of the changes is reflected immediately on the display. The OSCAR
Display Settings table describes each of the available display attributes.
NOTE: While changing OSCAR attributes, it is possible to scramble the screens, making it
difficult to correct the problem. If this occurs, reset the switch to its default OSCAR values by
pressing: Escape + Escape + Print Screen + F10 + Y + Enter
2.
Press Enter to save the settings and exit the menu.

Setting up a Scan Pattern

In scan mode, the switch automatically scans from port to port (server to
server). You can scan the entire system sequentially or designate a custom
scan pattern by specifying servers and durations.
To access the Scan screen:
1.
Press Print Screen then F2 to access the Advanced Menus screen.
2.
Highlight Setup - Scan and press Enter. The Scan Pattern Setup screen appears.
Figure 3.5: Scan Pattern Setup Screen
To scan all servers in the system:
1.
In the Scan Pattern Setup screen, press F10 to restore the defaults.
2.
In the Sec column, type the number of seconds (from 1 to 256) of desired
Delay Time before the scan moves to the next server in the sequence.
3.
Move the cursor to the next line or press the Down Arrow and repeat step
2 for each server, then press Enter.
4.
Highlight Commands - Scan to start the scan mode and press Enter.
.

Advertisement

Table of Contents
loading

Table of Contents