Message
Meaning
E__5
10V supply voltage for label
sensor low.
E__6
24V Voltage low
E__7
Material initialization failed
E__8
Error stepper motor driver
E__9
10V supply for label sensor too
high
E__10
Missing label on product
___0
Process error (Divide overflow)
___1
Illegal interrupt (processing error)
___2
Illegal bank interrupt (processing
error)
INTO
Illegal interrupt INTP0 (processing
error)
Release 12/07
How to solve
Short circuit in label sensor or cable.
Voltage regulator U14 is damaged.
Short circuit on an output. Total load too
high i.e. max is 3A for all outputs.
Voltage regulator U1 is damaged.
Change main board.
Check if the label web is threaded
through the label sensor
The stepper motor control has detected
an error. The fault is indicated by the
LED's on the driver.
Voltage regulator U14 damaged
One or several product could not be
labelled. Distance between products too
close. Increase speed of printer.
Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board
Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board
Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board
Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board.