Patton electronics 1003S User Manual

Asynchronous, 2-wire, carrier sense short range modem

Advertisement

Quick Links

USER
MANUAL
MODEL 1003
and 1003S
Asynchronous,
2-Wire, Carrier
Sense Short Range
Modem
Part #07M1003-B
Doc. #050021UB
Revised 4/28/98
An ISO-9001
Certified Company
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Advertisement

loading

Summary of Contents for Patton electronics 1003S

  • Page 1 USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem SALES OFFICE Part #07M1003-B Doc. #050021UB (301) 975-1000 Revised 4/28/98 TECHNICAL SUPPORT (301) 975-1007 An ISO-9001 http://www.patton.com Certified Company...
  • Page 2: Warranty Information

    1.0 WARRANTY INFORMATION 1.3 SERVICE Patton Electronics warrants all Model 1003 components to be free from defects, and will—at our option—repair or replace the product should All warranty and nonwarranty repairs must be returned freight it fail within one year from the first date of shipment. prepaid and insured to Patton Electronics.
  • Page 3: General Information

    Please be sure that the cable you use has no equalizers, conditioners, or other equipment installed that could affect the signal passed between The Model 1003S is a surge protected version of the Model 1002 that the two Model 1003s--they need dry, unconditioned metallic cable.
  • Page 4 A. Connecting to the RS-232 Interface. The Model 1003 and 1003S C. Two-Wire Connection Using Coax. When using coax for two- are designed to plug directly into the DB-25 (RS-232) interface of wire connection, the coax cable should be terminated with male a terminal or modem.
  • Page 5 Strip the outer insulation from the twisted pair about one inch from the end. 3. Strip back the insulation on each of the two wires about .25", Insert the strain relief assembly with the wire going through it into the slot in the bottom half of the modem case and seat it into the recess in the case.
  • Page 6 • Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher Surge Protection: Compliant with IEC 801.5 level 2, 1kV (Model AWG numbers than 26) 1003S Only) • Use of twisted pair with a resistance greater than the above Range: Up to 1 mile specifications may cause a reduction in maximum distance obtainable.
  • Page 7 APPENDIX C APPENDIX B PATTON MODEL 1003 PIN ASSIGNMENTS PATTON MODEL 1003 BLOCK DIAGRAM DIRECTION STANDARD "DCE" SETTING DIRECTION 1- (FG) Frame Ground 2- (TD) Transmit Data To Model 1003 3- (RD) Receive Data From Model 1003 4- (RTS) Request to Send To Model 1003 5- (CTS) Clear to Send From Model 1003...