Connecting the twisted pair wires to the EnviroNET

To connect the twisted pair wires to the EnviroNET:
1. Run the twisted pair wires from outside of the EnviroNET through the unscrewed glands (on the right) to
the inside of the unit.
2. Connect the appropriate wires to the appropriate slots in the terminal block. There should be one wire per
gland. Follow the wiring diagram that is on the inside of the EnviroNET door (see
Figure 8. Terminal block diagram (Displayed on the inside of the EnviroNET door)
3. Be sure to leave a little slack on the wires so that they are not stressed or pulled too tightly. Also, make sure
that the twisted pair wires are secured tightly in the terminal block.
4. To ensure that the cables are properly secured in the gland, tighten the gland by turning the loose pieces all
the way to the right using a Crescent® (adjustable) wrench.
Note
Wiring the terminal block
The black plugs for the brass glands on the bottom panel of the
EnviroNET should not be removed.
2 • Installing the EnviroNET
figure
8).