Patton electronics 2616RC Getting Started Manual page 63

T1/e1 tdm-digital access concentrator (t-dac)
Hide thumbs Also See for 2616RC:
Table of Contents

Advertisement

Model 2616RC T-DAC Getting Started Guide
LED
Location
SYSTEM
ETHERNET
CLK SOURCE
CLK ERROR
Front panel Yellow On solid Master Clock source has been lost and the 2616RC is using the
TEST MODE
Front panel Green
T1/E1
Front Panel Green
CONNECTIONS
(LEDs 1–16)
Fault analysis
Table 7. LED definitions (Continued)
Color
Status
Front
Green
Flash-
panel
ing
Off
Front
Green
On solid
panel
Off
Front
Green
On solid The 2616RC is set as the Master Clock source. No action rec-
panel
Flashing The 2616RC is set as the secondary clock source. No action
Off
Flashing Master Clock source and the Secondary Clock source have been
Off
On solid One or more T1/E1 ports or T1/E1 ports is in test mode.
Flashing One or more of the T1/E1 ports or the T1/E1 ports is in test
Off
On solid The ports are activated, linked, and operating normally.
Flashing One or more T1/E1 ports have errors.
Off
5 • Troubleshooting and maintenance
The Model 2616RC is operating normally. No action rec-
ommended.
The Model 2616RC is not functioning properly. As soon
as possible, unplug both power cables from the Model
2616RC, wait 30 seconds, then plug the cables back
into the Mode 2616RC to see if the problem disappears.
If the SYSTEM LED remains lit after the Model 2616RC
completes the power-up cycle, contact Patton Technical
Support to determine whether the T-DAC needs to be
replaced.
Link status is nominal for the Ethernet port. No action recom-
mended.
A valid link has not been detected.
Verify that an Ethernet cable is plugged into the hub, switch,
or workstation and the Ethernet port of the Model 2616RC.
Verify that the hub, switch, or workstation is powered on.
Verify that the correct straight-through or cross-over cable is
being used, depending on whether you are connecting to a
workstation (PC), hub, or switch.
Replace the cable. If the problem still exists, contact Patton Tech-
nical Support to determine if the T-DAC should be replaced.
ommended.
recommended.
The 2616RC is set as the slave, getting its clock from the H.110
Bus. No action recommended.
secondary source for its clock.
lost and the 2616RC is using its internal crystal for its clock.
No clock errors currently detected.
No action recommended.
No action recommended.
mode and errors have been received.
None of the T1/E1 ports is operating in test mode.
No action recommended.
No T1/E1 ports have been configured to establish a link.
See Chapter 3, "Configuring the T-DAC for operation" on
page 31 to configure the T1/E1 ports.
Meaning
63

Advertisement

Table of Contents
loading

Table of Contents