DSC Power608 Instruction Manual page 8

Hide thumbs Also See for Power608:
Table of Contents

Advertisement

PC5508 LED Keypad
Emergency Keys (All Keypads)
Press both * Keys for two seconds to send a FIRE transmission.
Press both
* Keys for two seconds to send an AUXILIARY transmission.
Press both
* Keys for two seconds to send a PANIC transmission.
* IMPORTANT NOTE (All Keypads): The Fire, Auxiliary and Panic keys will NOT function unless
programmed by the installer. If these keys are in service and the installer has enabled audible feedback,
holding down the key for two seconds will cause the keypad sounder to beep indicating that the input
has been accepted and transmission is underway.
8
Memory Light
Upon disarming, if an alarm has
occurred while the system was armed,
the Memory light will turn ON (See
"Disarming the System" on page 5).
Bypass Light
If the Bypass light is ON, one or more
zones are bypassed (See "Zone
Bypassing" on page 10).
Fire Light
If the Fire light is ON, a fire alarm has
occurred (See "Fire Alarm Operation"
on page 13).
Program Light
The Program light will flash when you are
programming access codes, or
performing other programming
functions. If someone is programming at
another keypad, the Program light will
turn ON to indicate that the system is
busy.
LCD5500Z Keypad
Display Lights (All Keypads)
Ready Light
If the Ready light is ON, the system is ready for arming. The system cannot be armed unless the Ready light is ON
(see "Arming the System" on page 3).
Armed Light
If the Armed light is ON, the system has been armed successfully.
Trouble or System Light
If the Trouble light is ON, see "Viewing Trouble Conditions" on page 11.
Important Note: Test system weekly and have any system trouble conditions
corrected by your alarm installer.
The Liquid Crystal Display (LCD)
displays prompts and system information
on two 16 character lines.
If "< >" appears, more information can be
accessed by using the arrow (< >) keys.
Press [<] to see the previous function or
item of information. Press [>] to advance
the display to next function or item of
information.
Press the keys on the number pad as
prompted by the LCD display to view
alarms or troubles, to arm and disarm the
system and to bypass zones.
To exit a function and return to the Ready
state, press [#].