Visonic POWERMAX+ Installer's Manual page 14

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAX+:
Table of Contents

Advertisement

READY 00:00
NEXT
NORMAL MODE
NEXT
USER SETTINGS
NEXT
INSTALLER MODE
OK
ENTER CODE
[installer code]
1. NEW INSTL CODE
NEXT
2. ENROLLING
NEXT
3. DEFINE ZONES
NEXT
OK
4. DEFINE PANEL
NEXT
5. DEFINE COMM
NEXT
6. DEFINE GSM
NEXT
7. DEFINE PWRLNK
NEXT
8. DEFINE OUTPUTS
NEXT
9. RECORD SPEECH
NEXT
10. DIAGNOSTICS
NEXT
11. USER SETTINGS
NEXT
12. FACTORY DEFLT
NEXT
13. SERIAL NUMBER
NEXT
14. START UL/DL
NEXT
<OK> TO EXIT
Note: The currently saved
options are displayed with
dark box at the right side of
the display. To review the
options, repeatedly click
NEXT or BACK until the
desired option is displayed,
then click OK (a dark box
will be displayed at the right
side).
14
NEXT
01: ENTRY DELAY 1
OK
entry dly1 00 s
entry dly1 15 s
entry dly1 30 s
entry dly1 45 s
entry dly1 60 s
entry dly1 3 m
entry dly1 4 m
OK
NEXT
05: ABORT TIME
OK
abort time 00 s
abort time 15 s
abort time 30 s
abort time 45 s
abort time 60 s
abort time 2 m
abort time 3 m
abort time 4 m
OK
NEXT
09: EXIT MODE
OK
restart exit
off by door
normal
OK
NEXT
13: SWINGER STOP
OK
shut after 1
shut after 2
shut after 3
in
USA
no shutdown
OK
NEXT
17: AUX BUTTON
OK
status
instant
PGM / X-10
OK
NEXT
21: BACK LIGHT
OK
always on
off after 10 s
OK
Note: Duress code is not
applicable to the UK.
NEXT
25: TAMPER OPTION
OK
zone tamper on
zone tamper off
OK
NEXT
29 BELL/REP. OPT
OK
EN standard
other
OK
33: AC FAIL REP
NEXT
OK
5 minutes
30 minutes
60 minutes
180 minutes
OK
Figure 4.4 - DEFINE PANEL Flow Chart
NEXT
02: ENTRY DELAY 2
OK
entry dly2 00 s
entry dly2 15 s
entry dly2 30 s
entry dly2 45 s
entry dly2 60 s
entry dly2 3 m
entry dly2 4 m
OK
NEXT
06: ALARM CANCEL
OK
cancel time 1 m
cancel time 5 m
cancel time 15 m
cancel time 60 m
cancel time 4 h
cancel inactive
in
OK
USA
NEXT
10: PIEZO BEEPS
11: TROUBLE BEEPS
OK
enable beeps
off when home
disable beeps
in
USA
OK
NEXT
14: CROSS ZONING
OK
cross zone ON
cross zone OFF
OK
NEXT
18: JAM DETECT
OK
UL (20/20)
EN (30/60)
class 6 (30/60)
disabled
OK
NEXT
22: DURESS
OK
duress code 2580
(Change the code or
enter 0000 to disable
duress function)
OK
NEXT
26: SIREN ON LINE
27:MEMORY PROMPT
OK
enable on fail
disable on fail
OK
NEXT
30: LOW-BAT ACK
OK
keyfob L-B on
keyfob L-B off
OK
NEXT
35: USER PERMIT
OK
Disable
Enable
in
OK
UK
NEXT
03: EXIT DELAY
OK
exit delay 30 s
exit delay 60 s
exit delay 90 s
exit delay 120 s
exit delay 3 m
exit delay 4 m
OK
NEXT
07: QUICK ARM
OK
quick arm ON
quick arm OFF
OK
Note: Force arm is not
applicable to the UK.
NEXT
OK
enable beeps
disable beeps
in
off at night
USA
OK
NEXT
15: SUPERVISION
OK
superv time 1 h
superv time 2 h
superv time 4 h
superv time 8 h
superv time 12 h
disable
OK
NEXT
19:LATCHKEY
OK
latchkey on
latchkey off
OK
NEXT
23: PIEZO SIREN
OK
piezo siren on
piezo siren off
OK
Not applicable
in the USA
NEXT
OK
enable
disable
OK
Not applicable
in the USA
NEXT
31: SCREEN SAVER
OK
scrn saver OFF
refresh by code
refresh by key
OK
NEXT
04: BELL TIME
OK
bell time 1 m
bell time 3 m
bell time 4 m
bell time 8 m
bell time 10 m
bell time 15 m
bell time 20 m
OK
NEXT
08: BYPASS
OK
manual bypass
no bypass
force arm
OK
NEXT
12: PANIC ALARM
OK
silent panic
audible panic
disable panic
OK
NEXT
16: NOT READY
OK
normal
in supervision
OK
NEXT
20: NOT ACTIVE
OK
no act time 3 h
no act time 6 h
no act time 12 h
no act time 24 h
no act time 48 h
no act time 72 h
no act disable
OK
24: RESET OPTION
NEXT
OK
user reset
enginner reset
OK
NEXT
28: DISARM OPTION
OK
any time
on entry all
on entry wirless
entry + away kp
in
UK
OK
NEXT
32: CONFIRM TIME
OK
disable
30 minutes
45 minutes
60 minutes
90 minutes
OK
DE5467IP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents